Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0424-00497
Permit Details
Apply Date:
04/17/2024
Applicant:
Celina Rodriguez
Description:
Bella Tierra Phase 3 1745-130
Permit Reviews
Permit Number - TC-MDP-0424-00497
Permit Status: Inspections complete
Permit Description: Bella Tierra Phase 3 1745-130
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/18/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/25/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0424-00497
Permit Status: Inspections complete
Permit Description: Bella Tierra Phase 3 1745-130
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
04/17/2024 | Post-Tension Inspection Report is required. |
04/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
04/17/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
04/19/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
04/19/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/22/2023 | THIS DOES NOT APPLY |
Conditions
Permit Number - TC-MDP-0424-00497
Permit Status: Inspections complete
Permit Description: Bella Tierra Phase 3 1745-130
Date | Description | Comments |
---|---|---|
04/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
11/22/2023 | THIS DOES NOT APPLY |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00497
Permite Description: Bella Tierra Phase 3 1745-130
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2024 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | 4/30/24: line not under test |
07/31/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Secure main water line. Water lines are not fully pressurized. Leak in master bathroom. Vanity to the right. (ABS). Provide long plate on both sides of hood vent and nail every hole for protection and reinforcement of top plate. Add blocking to register in hallway. 7/31/2024 |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00497
Permit Description: Bella Tierra Phase 3 1745-130
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2024 | COT - RSPL - Yard Water Line | Passed | 5/1/24: Line is under an air pressure test of 70# with no leaks. Okay to shade pipe and backfill trench. | |
05/01/2024 | COT - RSPL - Rough Soil | Passed | Passed on 4/30/24 by E. Adams. | |
05/31/2024 | COT - RSEL - Electrical Underground | Passed | ||
05/31/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
06/03/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
06/03/2024 | COT - RSBU - Preslab | Passed | ||
06/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Plywood sheathing for exterior shear walls is properly secured to studs per plan requirements. All masa clips and shear wall hold downs are properly nailed to bottom plates and wall studs. Bottom plates are secured with cut nails, titan bolts, or j-bolts. Okay to proceed with plumbing top out. | |
06/12/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly secured to top plate with nails and H2.5 hurricane ties. Plywood sheathing is securely attached to trusses with nails per plan. Okay to proceed with plumbing top out. | |
07/29/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is under a 15 pound pressure test with no leaks. | |
08/02/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 8/2/24: Corrections have been made, tub & shower are filled with water, air pressure is at 60 pounds on the water line. Okay to proceed with insulation and drywall installation. | |
08/06/2024 | BULD - Electrical Clearance | Passed | TEP ECO | |
08/22/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
09/09/2024 | COT - RSPL - Sewer | Passed | Sewer line is properly connected to underground plumbing. Okay to shade pipe and backfill trench. | |
10/03/2024 | COT - BULD - SWG Clearance | Passed | 10-3-24, verified equipment in place. Clearance issued to Southwest Gas. | |
10/25/2024 | COT - RSEL - Electrical Final | Passed | Construction is completed per plans. Okay to issue Certificate of Occupancy. | |
10/25/2024 | COT - RSEL - Outdoor Lighting | Passed | Outdoor lighting is installed and operational per plan and city requirements. | |
10/25/2024 | COT - RSME - Mechanical Final | Passed | Construction is completed per plans. Okay to issue Certificate of Occupancy. | |
10/25/2024 | COT - RSPL - Plumbing Final | Passed | Construction is completed per plans. Okay to issue Certificate of Occupancy. | |
10/25/2024 | ENGR Engineering Final | Passed | ||
10/25/2024 | RSBU - Building Final | Passed | Construction is completed per plans. Okay to issue Certificate of Occupancy. | |
10/25/2024 | RSBU - Building Progress | Passed | Construction is completed per plans. Okay to issue Certificate of Occupancy. |