Permit: TC-MDP-0424-00480
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
9798 E GRAY HAWK DR
Address NEW:
9798 E GRAY HAWK DR
Apply Date:
04/17/2024
Applicant:
Helen Ormsby
Description:
Casas del Cerrito H35G Model Plan
Permit Reviews
Permit Number - TC-MDP-0424-00480
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35G Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/29/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 01/30/2025 | APPROVED |
| 04/18/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/24/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0424-00480
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35G Model Plan
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0424-00480
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35G Model Plan
| Date | Description | Comments |
|---|---|---|
| 04/19/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 01/30/2025 | Post-Installed Anchor Inspection Report is required. | |
| 04/17/2024 | Post-Tension Inspection Report is required. | |
| 04/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 04/19/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 04/19/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00480
Permite Description: Casas del Cerrito H35G Model Plan
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/26/2024 | COT - RSPL - Backwater Valve | N/A | Not Ready | Not ready for inspection 11/26/24 |
| 11/26/2024 | COT - RSPL - Rough Soil | N/A | Not Ready | Not ready for inspection 11/26/24 |
| 11/26/2024 | COT - RSPL - Sewer | N/A | Not Ready | Not ready for inspection 11/26/24 |
| 11/26/2024 | COT - RSPL - Yard Water Line | N/A | Not Ready | Not ready for inspection 11/26/24 |
| 11/26/2024 | RSBU - Building Progress | N/A | Not Ready | Not ready for inspection 11/26/24 |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00480
Permit Description: Casas del Cerrito H35G Model Plan
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/27/2024 | COT - RSPL - Backwater Valve | Passed | Underground plumbing is connected to main sewer line with green tracer wire attached. Backwater valve is installed in line from clean outs to sewer connection. Entire system is under water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 11/27/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing is connected to main sewer line with green tracer wire attached. Backwater valve is installed in line from clean outs to sewer connection. Entire system is under water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 11/27/2024 | COT - RSPL - Sewer | Passed | Underground plumbing is connected to main sewer line with green tracer wire attached. Backwater valve is installed in line from clean outs to sewer connection. Entire system is under water test with no leaks. Okay to shade pipes and backfill trenches. | |
| 11/27/2024 | COT - RSPL - Yard Water Line | Passed | Water is installed in trench and connected to the water meter. Line is under street pressure with no leaks. Okay to shade pipe and backfill trench. | |
| 12/09/2024 | BULD - Electrical Clearance | Passed | 12-9-24, panel approved to be energized. ECO clearance issued to TEP. | |
| 12/09/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 12-9-24, excavation/rebar/zoning and preslab approved. Okay pour concrete. | |
| 12/09/2024 | COT - RSBU - Preslab | Passed | 12-9-24, excavation/rebar/zoning and preslab approved. Okay pour concrete. | |
| 12/09/2024 | COT - RSEL - Electrical Underground | Passed | 12-9-24, electrical underground approved. | |
| 12/09/2024 | COT - RSEL - Grounding/Bonding | Passed | 12-9-24, grounding/bonding approved. | |
| 12/18/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 12/18/24 corrections were made. | |
| 12/18/2024 | COT - RSBU - Roof Nailing | Passed | 12/17/24. Headers not to schedule in doorways. Re inspection required 12/18/24 corrections were made. |
|
| 01/03/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough in is complete. Okay to proceed with installation of insulation and drywall. | |
| 01/06/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 01/13/2025 | COT - RSBU - Interior Shear Bracing | Passed | Drywall shear walls are properly secured to the studs per plan requirements. Okay to proceed with tape, texture, and paint. | |
| 02/26/2025 | COT - BULD - SWG Clearance | Passed | 26 FEB 25 Southwest gas Clearance: SWG |
|
| 03/06/2025 | COT - RSEL - Electrical Final | Passed | Passed final 3/6/25 Clearance ECO | |
| 03/06/2025 | COT - RSEL - Outdoor Lighting | Passed | Passed final 3/6/25 | |
| 03/06/2025 | COT - RSME - Mechanical Final | Passed | Passed final 3/6/25 | |
| 03/06/2025 | COT - RSPL - Plumbing Final | Passed | Passed final 3/6/25 | |
| 03/06/2025 | RSBU - Building Final | Passed | Passed final 3/6/25 | |
| 03/06/2025 | RSBU - Building Progress | Passed | Passed final 3/6/25 | |
| 04/04/2025 | ENGR Engineering Final | Passed | Site is good. C of O ready. |