Start Date Submittal Complete Date Status  
06/12/2023 ZZZMODEL PERMIT REVIEW RESIDENTIAL v.2 06/14/2023 REQUIRES RESUBMIT Review Details
06/14/2023 RESTAMP - RESIDENTIAL v.1 06/20/2023 APPROVED Review Details
06/14/2023 ZZZMODEL PERMIT REVIEW RESIDENTIAL v.3 06/14/2023 APPROVED Review Details
05/03/2023 ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 06/05/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0423-00916
Permit Status: Complete
Permit Description: DUPLEX DUPLVAL82 T22-M0037
Total Outstanding Activity Conditions - 1
Date Name
06/05/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0423-00916
Permit Status: Complete
Permit Description: DUPLEX DUPLVAL82 T22-M0037
Date Description Comments
05/03/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0423-00916
Permite Description: DUPLEX DUPLVAL82 T22-M0037
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/25/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready Fire wall not complete, no DWV, no pressure on potable system

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0423-00916
Permit Description: DUPLEX DUPLVAL82 T22-M0037
Total Completed Inspections - 19
Date Description Inspector Results Comments
08/22/2023 COT - RSPL - Rough Soil Passed
08/22/2023 COT - RSPL - Sewer Passed
08/22/2023 COT - RSPL - Yard Water Line Passed
08/23/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
08/23/2023 COT - RSBU - Preslab Passed
08/23/2023 COT - RSEL - Grounding/Bonding Passed
09/18/2023 COT - RSBU - Exterior Clips/Sheathing Passed Exterior shear wall is properly nailed off. Window flashing and windows are installed correctly. Door frames and doors are installed. Roof sheathing is installed and properly nailed off okay to dry-in roof and prepare for stucco installation.
09/18/2023 COT - RSBU - Roof Nailing Passed Exterior shear wall is properly nailed off. Window flashing and windows are installed correctly. Door frames and doors are installed. Roof sheathing is installed and properly nailed off okay to dry-in roof and prepare for stucco installation.
09/25/2023 RSBU - Building Progress Passed
10/03/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved intermediates for units #1 and #2, okay to insulate progress areas
10/04/2023 BULD - Electrical Clearance Passed Approved 2 service panels at duplex, ECO Clearance to TEP is required for unit #1 and #2
11/21/23 clearance resent
12/08/2023 COT - RSBU - Interior Shear Bracing Passed
12/08/2023 COT - RSEL - Electrical Final Passed
12/08/2023 COT - RSEL - Electrical Underground Passed
12/08/2023 COT - RSEL - Outdoor Lighting Passed
12/08/2023 COT - RSME - Mechanical Final Passed
12/08/2023 COT - RSPL - Plumbing Final Passed
12/08/2023 RSBU - Building Final Passed
12/08/2023 ENGR Engineering Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-OPHA CORRECTIONS_V1.PDF DOCUMENTS VIEW