Permit: TC-MDP-0423-00886
Permit Details
Apply Date:
01/17/2024
Applicant:
Daria Hopkins
Description:
SFR MER1502580 T21-M0076 REV1 roof covering change
Permit Reviews
Permit Number - TC-MDP-0423-00886
Permit Status: Complete
Permit Description: SFR MER1502580 T21-M0076 REV1 roof covering change
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/14/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 06/17/2024 | APPROVED |
09/26/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/26/2024 | APPROVED |
01/18/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/24/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0423-00886
Permit Status: Complete
Permit Description: SFR MER1502580 T21-M0076 REV1 roof covering change
Date | Description | Comments |
---|---|---|
01/18/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
01/18/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
01/18/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
01/23/2024 | Post-Tension Inspection Report is required. | |
04/12/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
01/18/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
06/17/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
01/23/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0423-00886
Permit Description: SFR MER1502580 T21-M0076 REV1 roof covering change
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/05/2024 | COT - RSPL - Yard Water Line | Passed | ||
04/05/2024 | COT - RSPL - Sewer | Passed | ||
04/05/2024 | COT - RSPL - Rough Soil | Passed | ||
04/18/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
04/18/2024 | COT - RSBU - Preslab | Passed | ||
04/18/2024 | COT - RSEL - Electrical Underground | Passed | ||
04/18/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
05/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Exterior walls are properly secured to floor with red head bolts, shot pins, or masa clips. Shear wall hold down is properly installed in garage wall between garage and house. Okay to proceed with windows and door frames installation and stucco dry-in application. | |
05/06/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly installed and secured to the top plate with nails and H2.5 clips. Plywood sheathing is installed and properly nailed to trusses per code. | |
06/03/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with other work. | |
06/03/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is holding 10 pounds of compressed air with no leaks. Okay to proceed with next phase of construction. | |
06/03/2024 | BULD - Electrical Clearance | Passed | 6/3/24: The address label has been installed on the electrical panel. Ground wires are attached to Ufer ground and gas pipe line. | |
06/25/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
08/20/2024 | COT - BULD - SWG Clearance | Passed | SWG FOR METER ONLYM | |
08/28/2024 | COT - RSEL - Electrical Final | Passed | Construction of house is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Breakers for A/C unit is properly sized per manufacturer specifications. Outdoor lighting is properly installed per plans and city regulations. Okay to issue Certificate of Occupancy. | |
08/28/2024 | COT - RSEL - Outdoor Lighting | Passed | Outdoor lighting is properly installed per plans and city regulations. | |
08/28/2024 | COT - RSME - Mechanical Final | Passed | Construction of house is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Breakers for A/C unit is properly sized per manufacturer specifications. Outdoor lighting is properly installed per plans and city regulations. Okay to issue Certificate of Occupancy. | |
08/28/2024 | COT - RSPL - Plumbing Final | Passed | Construction of house is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Breakers for A/C unit is properly sized per manufacturer specifications. Outdoor lighting is properly installed per plans and city regulations. Okay to issue Certificate of Occupancy. | |
08/28/2024 | ENGR Engineering Final | Passed | ||
08/28/2024 | RSBU - Building Final | Passed | Construction of house is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Breakers for A/C unit is properly sized per manufacturer specifications. Outdoor lighting is properly installed per plans and city regulations. Okay to issue Certificate of Occupancy. | |
08/28/2024 | RSBU - Building Progress | Passed | Construction of house is complete. Mechanical, electrical, and plumbing fixtures are installed and fully functional. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Breakers for A/C unit is properly sized per manufacturer specifications. Outdoor lighting is properly installed per plans and city regulations. Okay to issue Certificate of Occupancy. |