Permit: TC-MDP-0423-00863
Permit Details
Apply Date:
05/02/2023
Applicant:
Mark Alteri
Description:
SFR CVPLAN3 T22-M0044
Permit Reviews
Permit Number - TC-MDP-0423-00863
Permit Status: Complete
Permit Description: SFR CVPLAN3 T22-M0044
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/04/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 05/05/2023 | APPROVED |
10/06/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 10/09/2023 | APPROVED |
10/09/2023 | RESTAMP - RESIDENTIAL v.1 | 10/09/2023 | APPROVED |
09/21/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/21/2023 | APPROVED |
Conditions
Permit Number - TC-MDP-0423-00863
Permit Status: Complete
Permit Description: SFR CVPLAN3 T22-M0044
Date | Description | Comments |
---|---|---|
05/05/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. | |
05/04/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
09/21/2023 | Post-Tension Inspection Report is required. | |
05/04/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
05/05/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0423-00863
Permite Description: SFR CVPLAN3 T22-M0044
Total Outstanding Inspections - 6
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/31/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Not ready. Add 16 gauge metal straps to the top plate and 3" vent line. Add blocking underneath tub, register chase and laundry room. Add fire foam to top penetrations that are not being utilized. Receptacle in master bedroom needs to be moved over to follow 6' 12' rule. Secure EV line. Fully pressurize pex lines. Add smoke detector near bedrooms per plan. 8/31/2023 |
11/27/2023 | COT - RSBU - Masonry Pregrout | N/A | Not Applicable | |
11/28/2023 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 11/28/23: no ladder to check AC disconnect, sinks don't have p traps installed, toilet missing at downstairs bathroom, condensation line exterior needs coupling pointing down installed |
11/28/2023 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 11/28/23: no ladder to check AC disconnect, sinks don't have p traps installed, toilet missing at downstairs bathroom, condensation line exterior needs coupling pointing down installed |
11/28/2023 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 11/28/23: no ladder to check AC disconnect, sinks don't have p traps installed, toilet missing at downstairs bathroom, condensation line exterior needs coupling pointing down installed |
11/28/2023 | RSBU - Building Final | N/A | Re-inspection required | 11/28/23: no ladder to check AC disconnect, sinks don't have p traps installed, toilet missing at downstairs bathroom, condensation line exterior needs coupling pointing down installed |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0423-00863
Permit Description: SFR CVPLAN3 T22-M0044
Total Completed Inspections - 23