Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0423-00856
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
9998 S ARNOLD RANCH CT
Address NEW:
9998 S ARNOLD RANCH CT
Apply Date:
04/13/2023
Applicant:
Amy Stokes, Operations Accountant
Description:
SFR RKK35I T21-M0091, Revision-1 frame walk redlines, Revision-2 Structural calcs and Post grade,
Permit Reviews
Permit Number - TC-MDP-0423-00856
Permit Status: Complete
Permit Description: SFR RKK35I T21-M0091, Revision-1 frame walk redlines, Revision-2
Structural calcs and Post grade,
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/17/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 04/21/2023 | APPROVED |
| 09/25/2023 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/26/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0423-00856
Permit Status: Complete
Permit Description: SFR RKK35I T21-M0091, Revision-1 frame walk redlines, Revision-2
Structural calcs and Post grade,
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 04/18/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
| 04/18/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0423-00856
Permit Status: Complete
Permit Description: SFR RKK35I T21-M0091, Revision-1 frame walk redlines, Revision-2
Structural calcs and Post grade,
| Date | Description | Comments |
|---|---|---|
| 04/17/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 04/17/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 04/17/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 09/26/2023 | Post-Tension Inspection Report is required. | |
| 04/17/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 04/18/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0423-00856
Permite Description: SFR RKK35I T21-M0091, Revision-1 frame walk redlines, Revision-2
Structural calcs and Post grade,
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/10/2023 | COT - RSPL - Backwater Valve | N/A | Not Applicable | |
| 07/18/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 7/18/23: No attic access. Second attic access requires 30" of headroom space per code. Provide letter from engineer for ok to make access through shear wall. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0423-00856
Permit Description: SFR RKK35I T21-M0091, Revision-1 frame walk redlines, Revision-2
Structural calcs and Post grade,
Total Completed Inspections - 21