Permit Number - TC-MDP-0326-00153
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Start Date Submittal Complete Date Status  
03/19/2026 SITE FROM MODEL PERMIT - PRODUCTION v.1 04/02/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0326-00153
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Outstanding Activity Conditions - 6
Date Name
03/13/2026 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
03/13/2026 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.

Conditions

Permit Number - TC-MDP-0326-00153
Permit Status: Inspections
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Date Description Comments
03/13/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
03/13/2026 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0326-00153
Permit Description: Mirador Point 2467-225 (2024 IRC) (Model Master Plan TC-MDP-0226-00092)
Total Completed Inspections - 6
Date Description Inspector Results Comments
04/14/2026 COT - RSPL - Rough Soil Passed 04/14/2026
Holding under test. Ok to backfill, shading required.
04/14/2026 COT - RSPL - Yard Water Line Passed 04/14/2026
Holding under test to meter. Ok to backfill, shading required.
04/14/2026 COT - RSPL - Sewer Passed 04/14/2026
Holding under test to HCS. Ok to backfill, shading required.
04/20/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 04/20/2026
Approved per plan & reinforcements. Okay for concrete placement.
04/20/2026 COT - RSBU - Preslab Passed 04/20/2026
Approved per plan & reinforcements. Okay for concrete placement.
04/20/2026 COT - RSEL - Electrical Underground Passed