Permit: TC-MDP-0325-00206
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
9603 E MEOLA DR
Address NEW:
9603 E MEOLA DR
Apply Date:
09/02/2025
Applicant:
Celina Rodriguez
Description:
Mirador Point 1201 Plan (Model master plan TC-MDP-0125-00062)
Permit Reviews
Permit Number - TC-MDP-0325-00206
Permit Status: Inspections complete
Permit Description: Mirador Point 1201 Plan (Model master plan TC-MDP-0125-00062)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/02/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/09/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0325-00206
Permit Status: Inspections complete
Permit Description: Mirador Point 1201 Plan (Model master plan TC-MDP-0125-00062)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 03/25/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 09/02/2025 | Post-Installed Anchor Inspection Report is required. |
| 09/02/2025 | Post-Tension Inspection Report is required. |
| 09/02/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 09/09/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0325-00206
Permit Status: Inspections complete
Permit Description: Mirador Point 1201 Plan (Model master plan TC-MDP-0125-00062)
| Date | Description | Comments |
|---|---|---|
| 09/09/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 03/25/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0325-00206
Permite Description: Mirador Point 1201 Plan (Model master plan TC-MDP-0125-00062)
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2025 | COT - RSPL - Rough Soil | N/A | Re-inspection required | Too much caliche and rocks in trench. |
| 09/25/2025 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | |
| 10/03/2025 | COT - RSPL - Backwater Valve | N/A | Not Applicable | |
| 10/27/2025 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 10/27/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 01/12/2026 | RSBU - Building Final | N/A | Re-inspection required | 01/12/2026 Dead front needs three breakers slots plugged and 15A breaker labeled, left of stove receptacle needs to be GFCI & has hot/neural wires reversed, cannot verify bedroom & bathroom circuits, smoke detector not wired in primary bedroom, garage service entry door needs to be self-closing, water heater disconnect not wired. |
| 01/12/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 01/12/2026 Dead front needs three breakers slots plugged and 15A breaker labeled, left of stove receptacle needs to be GFCI & has hot/neural wires reversed, cannot verify bedroom & bathroom circuits, smoke detector not wired in primary bedroom, garage service entry door needs to be self-closing, water heater disconnect not wired. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0325-00206
Permit Description: Mirador Point 1201 Plan (Model master plan TC-MDP-0125-00062)
Total Completed Inspections - 19