Permit Reviews

Permit Number - TC-MDP-0324-00327
Permit Status: Complete
Permit Description: SFR PVCS1041 T22-M0050
Start Date Submittal Complete Date Status  
07/26/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/26/2024 APPROVED Review Details
03/28/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 04/04/2024 APPROVED Review Details
07/08/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/08/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0324-00327
Permit Status: Complete
Permit Description: SFR PVCS1041 T22-M0050
Date Description Comments
04/01/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
03/20/2024 Post-Tension Inspection Report is required.
03/20/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
03/20/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
04/01/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0324-00327
Permite Description: SFR PVCS1041 T22-M0050
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/16/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 7/16/24:penetrations in vapor barrier need to be sealed. Top plate penetrations need to be sealed. Lath incomplete at side porch window.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0324-00327
Permit Description: SFR PVCS1041 T22-M0050
Total Completed Inspections - 23
Date Description Inspector Results Comments
04/24/2024 COT - RSPL - Yard Water Line Passed
04/24/2024 COT - RSPL - Sewer Passed
04/24/2024 COT - RSPL - Rough Soil Passed
04/24/2024 COT - RSPL - Backwater Valve Passed
04/30/2024 COT - RSBU - Preslab Passed
04/30/2024 COT - RSEL - Electrical Underground Passed
04/30/2024 COT - RSEL - Grounding/Bonding Passed
04/30/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
06/12/2024 COT - RSBU - Exterior Clips/Sheathing Passed
06/12/2024 COT - RSBU - Roof Nailing Passed
06/18/2024 COT - RSBU - Firewall/Fire Barrier/Firestop Passed
07/01/2024 BULD - Electrical Clearance Passed 7/1/2024 clearance for TEP ECO.
07/15/2024 COT - RSPL - Gas Pressure Test Passed
07/17/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
07/31/2024 COT - RSBU - Interior Shear Bracing Passed
09/20/2024 COT - BULD - SWG Clearance Passed SWG FOR METER ONLY
09/27/2024 RSBU - Building Progress Passed
09/27/2024 ENGR Engineering Final Passed Common area accessible access needs to be completed to the front of home with no interruptions.

Several times it has been mentioned about the common area ramps and railings. These still need to be addressed and will hold up the final inspections on this project. This also includes any and all access to the front of the home that has a ramp in the easement area for the common area walkways.
09/27/2024 COT - RSEL - Electrical Final Passed Construction is complete per plans. Okay to issue Certificate of Occupancy.
09/27/2024 COT - RSEL - Outdoor Lighting Passed Construction is complete per plans. Okay to issue Certificate of Occupancy.
09/27/2024 COT - RSME - Mechanical Final Passed Construction is complete per plans. Okay to issue Certificate of Occupancy.
09/27/2024 RSBU - Building Final Passed Construction is complete per plans. Okay to issue Certificate of Occupancy.
09/27/2024 COT - RSPL - Plumbing Final Passed Construction is complete per plans. Okay to issue Certificate of Occupancy.

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
PT REPORT LOT 57 COMPLETE-2024-07-08_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CBT 57 PP FOR PERMIT _V1.PDF DOCUMENTS VIEW
CBT 57 PT CERT-2024-03-26_V1.PDF DOCUMENTS VIEW