Permit: TC-MDP-0323-00804
Permit Details
Apply Date:
04/11/2023
Applicant:
Celina Rodriguez
Description:
SFR BT2685-228 T22-M0012
Permit Reviews
Permit Number - TC-MDP-0323-00804
Permit Status: Complete
Permit Description: SFR BT2685-228 T22-M0012
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/14/2023 | ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 | 04/19/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0323-00804
Permit Status: Complete
Permit Description: SFR BT2685-228 T22-M0012
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
06/15/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
06/15/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0323-00804
Permit Status: Complete
Permit Description: SFR BT2685-228 T22-M0012
Date | Description | Comments |
---|---|---|
04/17/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. | |
04/14/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
04/14/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
03/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
04/17/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0323-00804
Permite Description: SFR BT2685-228 T22-M0012
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/16/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1- Ufer connection to Grounding Electrode Conductor is not accessible. 2-Electrical box at top of stairs has no wires. 3- Fire block duct chase ceiling by stairs. 4-boxes at Kitchen island are not wired. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0323-00804
Permit Description: SFR BT2685-228 T22-M0012
Total Completed Inspections - 21