Permit: TC-MDP-0323-00803
Permit Details
Apply Date:
10/29/2023
Applicant:
Celina Rodriguez
Description:
SFR BT2685-228 T22-M0012
Permit Reviews
Permit Number - TC-MDP-0323-00803
Permit Status: Inspections
Permit Description: SFR BT2685-228 T22-M0012
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/31/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/19/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0323-00803
Permit Status: Inspections
Permit Description: SFR BT2685-228 T22-M0012
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
10/31/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
11/01/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
11/01/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/01/2024 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0323-00803
Permit Status: Inspections
Permit Description: SFR BT2685-228 T22-M0012
Date | Description | Comments |
---|---|---|
10/31/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
03/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0323-00803
Permite Description: SFR BT2685-228 T22-M0012
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/27/2024 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. |
COT - RSBU - Interior Shear Bracing | N/A | Scheduled |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0323-00803
Permit Description: SFR BT2685-228 T22-M0012
Total Completed Inspections - 10
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2024 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading is required. 11/21/2024 | |
11/21/2024 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading is required. 11/21/2024 | |
11/21/2024 | COT - RSPL - Yard Water Line | Passed | 60psi air test approved. Okay to backfill. Shading required. 11/21/2024 | |
11/27/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
11/27/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
11/27/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is in place and properly spaced, masa clips and shear wall hold downs are installed on forms as required, underground plumbing pipes are properly wrapped with foam, underground electrical for kitchen island is installed, and Ufer ground is in place on transformer side of garage. Okay to pour concrete. | |
12/20/2024 | COT - RSBU - Roof Nailing | Passed | 12/20/24 corrections made | |
12/20/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 12/20/24 corrections made | |
01/22/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 1/22/25 pass | |
01/22/2025 | COT - RSPL - Gas Pressure Test | Passed | 1/22/25 pass |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0323-00803
Status: Inspections
Description: SFR BT2685-228 T22-M0012
Scheduled Date | Description | Entered By | Entered Date |
---|---|---|---|
02/06/2025 | COT - RSBU - Interior Shear Bracing | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.