Start Date Submittal Complete Date Status  
05/08/2023 ZZZMODEL PERMIT REVIEW RESIDENTIAL v.1 05/12/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0323-00751
Permit Status: Issued
Permit Description: SFR LENNLE4001 T22-M0045
Total Outstanding Activity Conditions - 7
Date Name
05/08/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
05/08/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
05/08/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
05/12/2023 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
05/12/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
07/18/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/18/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Conditions

Permit Number - TC-MDP-0323-00751
Permit Status: Issued
Permit Description: SFR LENNLE4001 T22-M0045
Date Description Comments
03/16/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0323-00751
Permit Description: SFR LENNLE4001 T22-M0045
Total Completed Inspections - 20
Date Description Inspector Results Comments
06/22/2023 COT - RSPL - Yard Water Line Passed
06/22/2023 COT - RSPL - Sewer Passed
06/22/2023 COT - RSPL - Rough Soil Passed
07/10/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Ufer ground is in place and connected to the rebar reinforcement. Post tension cabling is laid out per plans and properly supported off the ground. Monolithic footing are properly dug. Okay to pour concrete slab and footings.
07/10/2023 COT - RSBU - Preslab Passed Ufer ground is in place and connected to the rebar reinforcement. Post tension cabling is laid out per plans and properly supported off the ground. Monolithic footing are properly dug. Okay to pour concrete slab and footings.
07/10/2023 COT - RSEL - Electrical Underground Passed Underground electrical for kitchen island is in place. Okay to pour concrete slab.
07/10/2023 COT - RSEL - Grounding/Bonding Passed Ufer ground is in place and connected to the rebar reinforcement. Post tension cabling is laid out per plans and properly supported off the ground. Monolithic footing are properly dug. Okay to pour concrete slab and footings.
08/04/2023 COT - RSBU - Roof Nailing Passed
08/10/2023 COT - RSBU - Exterior Clips/Sheathing Passed
09/20/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
09/20/2023 BULD - Electrical Clearance Passed
09/20/2023 COT - RSPL - Gas Pressure Test Passed
09/27/2023 COT - RSBU - Interior Shear Bracing Passed
01/22/2024 COT - BULD - SWG Clearance Passed
02/08/2024 COT - RSEL - Electrical Final Passed
02/08/2024 COT - RSEL - Outdoor Lighting Passed
02/08/2024 COT - RSME - Mechanical Final Passed
02/08/2024 COT - RSPL - Plumbing Final Passed
02/08/2024 RSBU - Building Final Passed
02/22/2024 ENGR Engineering Final Passed Please ensure that the clean out pipes in the front yard are repaired and cut down to grade so only the cap is showing.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LE2_5, 61_ 4001 MODEL MASTER_V1.PDF DOCUMENTS VIEW
LE2 61 4001 AL8_V1.PDF DOCUMENTS VIEW
LE2_5, 61_ 4001 SIC-2023-05-06_V1.PDF DOCUMENTS VIEW