Permit: TC-MDP-0224-00218
Permit Details
Apply Date:
04/10/2024
Applicant:
Daria Hopkins
Description:
SFR MER1502320 T21-M0070 REV1 roof covering change
Permit Reviews
Permit Number - TC-MDP-0224-00218
Permit Status: Complete
Permit Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/12/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/18/2024 | APPROVED |
08/23/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/23/2024 | APPROVED |
11/07/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 11/08/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0224-00218
Permit Status: Complete
Permit Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Date | Description | Comments |
---|---|---|
04/15/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
04/15/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
04/15/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
04/15/2024 | Post-Tension Inspection Report is required. | |
02/14/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
02/14/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
04/15/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0224-00218
Permit Description: SFR MER1502320 T21-M0070 REV1 roof covering change
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2024 | COT - RSPL - Rough Soil | Passed | ||
06/21/2024 | COT - RSPL - Sewer | Passed | ||
06/21/2024 | COT - RSPL - Yard Water Line | Passed | ||
06/28/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is evenly spaced and correctly installed, underground plumbing is properly wrapped with foam, underground electrical for kitchen island is installed, additional rebar reinforcement is properly installed per plan, and Ufer ground is installed in footing. Okay to proceed with pouring concrete. | |
06/28/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is evenly spaced and correctly installed, underground plumbing is properly wrapped with foam, underground electrical for kitchen island is installed, additional rebar reinforcement is properly installed per plan, and Ufer ground is installed in footing. Okay to proceed with pouring concrete. | |
06/28/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is evenly spaced and correctly installed, underground plumbing is properly wrapped with foam, underground electrical for kitchen island is installed, additional rebar reinforcement is properly installed per plan, and Ufer ground is installed in footing. Okay to proceed with pouring concrete. | |
06/28/2024 | COT - RSEL - Grounding/Bonding | Passed | Concrete forms are set, post tension cabling is evenly spaced and correctly installed, underground plumbing is properly wrapped with foam, underground electrical for kitchen island is installed, additional rebar reinforcement is properly installed per plan, and Ufer ground is installed in footing. Okay to proceed with pouring concrete. | |
07/22/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Exterior and interior plywood shear walls are properly installed, bolted, and nailed per the plans. All masa clips are properly nailed to bottom plate, all shear wall hold downs are properly nailed to wall studs, and titan bolts are installed were joints in bottom plate happened. Okay to proceed with rough-in of mechanical, electrical, and plumbing. | |
07/22/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly installed and secured to the top plate with nails and H2.5 clips. Roof sheathing is properly secured to the roof trusses with nails and staples. | |
08/19/2024 | BULD - Electrical Clearance | Passed | TEP ECO | |
08/19/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
08/20/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
09/03/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
10/23/2024 | COT - BULD - SWG Clearance | Passed | 10/23/24:SWG clearance ok for meter tag | |
10/29/2024 | COT - RSEL - Electrical Final | Passed | ||
10/29/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
10/29/2024 | COT - RSME - Mechanical Final | Passed | ||
10/29/2024 | COT - RSPL - Plumbing Final | Passed | ||
10/29/2024 | ENGR Engineering Final | Passed | ||
10/29/2024 | RSBU - Building Final | Passed | ||
10/29/2024 | RSBU - Building Progress | Passed |