Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
02/05/2024
Applicant:
Craig Morczynski
Description:
SFR LENNLE4001 T22-M0045

Permit Reviews

Permit Number - TC-MDP-0224-00163
Permit Status: Issued
Permit Description: SFR LENNLE4001 T22-M0045
Start Date Submittal Complete Date Status  
03/13/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 04/02/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0224-00163
Permit Status: Issued
Permit Description: SFR LENNLE4001 T22-M0045
Total Outstanding Activity Conditions - 6
Date Name
02/05/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
03/26/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
03/26/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
03/26/2024 Post-Tension Inspection Report is required.
03/26/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
07/14/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Conditions

Permit Number - TC-MDP-0224-00163
Permit Status: Issued
Permit Description: SFR LENNLE4001 T22-M0045
Date Description Comments
02/05/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
03/16/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/14/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
03/26/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0224-00163
Permit Description: SFR LENNLE4001 T22-M0045
Total Completed Inspections - 15
Date Description Inspector Results Comments
06/04/2024 COT - RSPL - Rough Soil Passed
06/04/2024 COT - RSPL - Sewer Passed
06/04/2024 COT - RSPL - Yard Water Line Passed
06/12/2024 COT - RSBU - Preslab Passed
06/12/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
06/12/2024 COT - RSEL - Electrical Underground Passed
06/12/2024 COT - RSEL - Grounding/Bonding Passed
08/08/2024 COT - RSBU - Exterior Clips/Sheathing Passed Corrections were made. 8/8/2024
08/08/2024 COT - RSBU - Roof Nailing Passed Corrections were made. 8/8/2024
09/26/2024 COT - RSPL - Gas Pressure Test Passed
09/26/2024 RSBU - Building Progress Passed
10/02/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed DWV not on test. Remove wiring from gusset plates. Refrigerator calls to be on dedicated circuit. Multiple tears in flex ducts. Incomplete lath at SGD. Seal tears in vapor barrier at SGD. 9/26/2024
10/2/24: corrections made
10/16/2024 COT - RSBU - Interior Shear Bracing Passed Passed shear wall inspection 10/16/24
12/10/2024 BULD - Electrical Clearance Passed Ready for power CLEARANCE ECO
12/17/2024 COT - BULD - SWG Clearance Passed Passed SWG CLEARANCE 12/17/24

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LE II LOT 9 - PERMIT_V1.PDF DOCUMENTS VIEW
LE II LOT 9 - SIC-2024-03-11_V1.PDF DOCUMENTS VIEW