Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
01/24/2024
Applicant:
Craig Morczynski
Description:
SFR LENNLE4005 T22-M0049

Permit Reviews

Permit Number - TC-MDP-0124-00137
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Start Date Submittal Complete Date Status  
03/13/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 03/22/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0124-00137
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Total Outstanding Activity Conditions - 6
Date Name
01/24/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
03/22/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
03/22/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
03/22/2024 Post-Tension Inspection Report is required.
03/22/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
07/18/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Conditions

Permit Number - TC-MDP-0124-00137
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Date Description Comments
01/24/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/18/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
03/22/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0124-00137
Permite Description: SFR LENNLE4005 T22-M0049
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/05/2024 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required Missing an extra stud at floor GT. First floor. Missing hanger at header at stairway. Add straps to SGD. Second floor bottom plate not nailed per schedule. Add blocking to landings. 8/5/2024
10/22/2024 COT - RSBU - Interior Shear Bracing N/A Re-inspection required 10/22/24: fasteners shall be 3/8" from edges and shall penetrate no more than 1/8". Garage west wall stud spacing greater than 16"o.c, not ready

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0124-00137
Permit Description: SFR LENNLE4005 T22-M0049
Total Completed Inspections - 14
Date Description Inspector Results Comments
06/04/2024 COT - RSPL - Rough Soil Passed
06/04/2024 COT - RSPL - Sewer Passed
06/04/2024 COT - RSPL - Yard Water Line Passed
06/12/2024 COT - RSBU - Preslab Passed
06/12/2024 COT - RSEL - Electrical Underground Passed
06/12/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
06/12/2024 COT - RSEL - Grounding/Bonding Passed
08/08/2024 COT - RSBU - Exterior Clips/Sheathing Passed Corrections were made. 8/8/2024
08/08/2024 COT - RSBU - Roof Nailing Passed Corrections were made. 8/8/2024
09/13/2024 BULD - Electrical Clearance Passed Clearance for TEP ECO 9\13\24
10/02/2024 COT - RSPL - Gas Pressure Test Passed
10/02/2024 RSBU - Building Progress Passed
10/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
10/23/2024 COT - RSBU - Interior Shear Bracing Passed 10-23-24, okay to tape and texture.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LE II LOT 94 - PERMIT_V1.PDF DOCUMENTS VIEW
LE II LOT 94 - SIC-2024-03-11_V1.PDF DOCUMENTS VIEW