Permit: TC-MDP-0124-00094
Permit Details
Apply Date:
01/17/2024
Applicant:
Celina Rodriguez
Description:
SFR BT1262-130 T22-M0016
Permit Reviews
Permit Number - TC-MDP-0124-00094
Permit Status: Inspections complete
Permit Description: SFR BT1262-130 T22-M0016
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/01/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 02/06/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0124-00094
Permit Status: Inspections complete
Permit Description: SFR BT1262-130 T22-M0016
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
01/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
02/01/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
02/01/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
02/01/2024 | Post-Tension Inspection Report is required. |
02/01/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0124-00094
Permit Status: Inspections complete
Permit Description: SFR BT1262-130 T22-M0016
Date | Description | Comments |
---|---|---|
01/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0124-00094
Permit Description: SFR BT1262-130 T22-M0016
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/29/2024 | COT - RSPL - Yard Water Line | Passed | ||
02/29/2024 | COT - RSPL - Rough Soil | Passed | ||
02/29/2024 | COT - RSPL - Sewer | Passed | ||
03/06/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
03/06/2024 | COT - RSBU - Preslab | Passed | ||
03/06/2024 | COT - RSEL - Electrical Underground | Passed | ||
03/06/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
04/01/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | All bolts are properly installed, all clips for bottom plates are nailed to plate, all shear wall sheathing is properly nailed and secured to studs, and all rafters have h2.5 clips properly nailed to top plate. Okay to proceed with dry-in and stucco foam and lath application. | |
04/01/2024 | COT - RSBU - Roof Nailing | Passed | Roof sheathing is properly nailed off, every rafter has a h2.5 clip holding it down to the top plate and is properly nailed. Okay to proceed with dry-in of roof. | |
05/02/2024 | BULD - Electrical Clearance | Passed | ||
05/03/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
05/03/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
05/17/2024 | COT - RSBU - Interior Shear Bracing | Passed | Drywall is properly installed and secured to studs per shear wall detail in plans. Okay to proceed with tape, texture, and paint of walls and ceilings. | |
07/12/2024 | COT - BULD - SWG Clearance | Passed | Gas valves are installed at all gas appliance locations. SWG Clearance issued for this project. | |
07/12/2024 | RSBU - Building Progress | Passed | Project is in punch list, working on getting ready for final inspections. | |
07/19/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
07/19/2024 | COT - RSEL - Electrical Final | Passed | ||
07/19/2024 | COT - RSME - Mechanical Final | Passed | ||
07/19/2024 | COT - RSPL - Plumbing Final | Passed | ||
07/19/2024 | RSBU - Building Final | Passed | ||
07/19/2024 | ENGR Engineering Final | Passed |