Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0123-00316
Permit Details
Apply Date:
01/04/2024
Applicant:
Garland Shaw
Description:
SFR PANT2022 T22-M0073
Permit Reviews
Permit Number - TC-MDP-0123-00316
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/01/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 03/11/2024 | APPROVED |
01/26/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 02/08/2024 | APPROVED |
01/04/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 01/16/2024 | REQUIRES RESUBMIT |
02/27/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/27/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00316
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
01/04/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
01/12/2024 | Post-Tension Inspection Report is required. |
03/09/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0123-00316
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Date | Description | Comments |
---|---|---|
01/04/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
06/15/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
06/15/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
01/12/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-0123-00316
Permite Description: SFR PANT2022 T22-M0073
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | Not Applicable-No gas to building. |
08/30/2024 | COT - BULD - SWG Clearance | N/A | Not Applicable | Not Applicable-No gas to building. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0123-00316
Permit Description: SFR PANT2022 T22-M0073
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2024 | COT - RSPL - Backwater Valve | Passed | ||
04/25/2024 | COT - RSPL - Rough Soil | Passed | ||
04/25/2024 | COT - RSPL - Sewer | Passed | ||
04/25/2024 | COT - RSPL - Yard Water Line | Passed | ||
05/10/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade. | |
05/10/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade. | |
05/10/2024 | COT - RSEL - Grounding/Bonding | Passed | Concrete forms are set, post tension cabling is installed, underground electrical is in place, Ufer ground is in place on left side of garage, required shear wall hold downs are in place and connected to rebar reinforcement, masa clips are evenly spaced around outside edge of form, and all underground plumbing pipes are wrapped with foam and all bathtub or shower stall drain lines are blocked out properly. Okay to pour concrete for footings and slab on grade. | |
06/05/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Plywood sheathing is properly secured to studs with nails per plan requirements. Shear wall hold downs are properly nailed to studs. Straps are installed at headers of large openings. Okay to proceed with rough-in of mechanical, electrical, and plumbing. | |
06/05/2024 | COT - RSBU - Roof Nailing | Passed | Roof sheathing is properly installed and attached to trusses with nails per plans. Trusses are secured to top plate with H2.5 clips. Okay to proceed. | |
06/17/2024 | COT - RSEL - Electrical Underground | Passed | Sweep and conduit are properly secured to electrical panel and ran out to TEP's transformer. Okay to shade conduit and backfill trench. | |
06/21/2024 | BULD - Electrical Clearance | Passed | ||
08/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with insulation and drywall installation work. | |
08/30/2024 | COT - RSBU - Interior Shear Bracing | Passed | Not required, no interior shear walls on building. |