Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Address:
2485 S CLOVIS PL
Apply Date:
09/21/2023
Applicant:
Garland Shaw
Description:
SFR PANT2022 T22-M0073

Permit Reviews

Permit Number - TC-MDP-0123-00300
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Start Date Submittal Complete Date Status  
09/22/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 09/27/2023 REQUIRES RESUBMIT Review Details
09/28/2023 SITE FROM MODEL PERMIT - PRODUCTION v.2 10/03/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0123-00300
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Total Outstanding Activity Conditions - 3
Date Name
06/15/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
09/22/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
10/02/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0123-00300
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Date Description Comments
06/15/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
09/22/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0123-00300
Permite Description: SFR PANT2022 T22-M0073
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
09/05/2024 COT - BULD - SWG Clearance N/A Not Applicable Not Applicable--there is no gas in this subdivision.
09/05/2024 RSBU - Building Progress N/A Partial Pass Construction crews are completing interior finishes and fixtures. Sidewalks and driveways are not poured.
09/05/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable Not Applicable--there is no gas in this subdivision.
09/17/2024 COT - RSEL - Outdoor Lighting N/A Not Ready 9/17/24: not ready needed permit extended.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0123-00300
Permit Description: SFR PANT2022 T22-M0073
Total Completed Inspections - 13
Date Description Inspector Results Comments
12/14/2023 COT - RSPL - Backwater Valve Passed
12/14/2023 COT - RSPL - Rough Soil Passed
12/14/2023 COT - RSPL - Sewer Passed
12/14/2023 COT - RSPL - Yard Water Line Passed
12/22/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
12/22/2023 COT - RSBU - Preslab Passed
12/22/2023 COT - RSEL - Grounding/Bonding Passed
01/25/2024 COT - RSBU - Exterior Clips/Sheathing Passed
01/25/2024 COT - RSBU - Roof Nailing Passed
01/31/2024 BULD - Electrical Clearance Passed TEP ECO
01/31/2024 COT - RSEL - Electrical Underground Passed
03/27/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
04/03/2024 COT - RSBU - Interior Shear Bracing Passed Drywall is properly screwed to studs and rafters. Okay to proceed with tape, texture, and paint.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
RESPONSE LETTER LOT 24. 2453 S CLOVIS_V1.PDF DOCUMENTS VIEW
SI CERT LOT 20_V1.PDF DOCUMENTS VIEW
SITE PLAN LOT 24 00300_V2.PDF DOCUMENTS VIEW