Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0123-00296
Permit Details
Apply Date:
10/30/2023
Applicant:
Garland Shaw
Description:
SFR PANT2022 T22-M0073
Permit Reviews
Permit Number - TC-MDP-0123-00296
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/30/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/02/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00296
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
06/15/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
10/30/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/01/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0123-00296
Permit Status: Issued
Permit Description: SFR PANT2022 T22-M0073
Date | Description | Comments |
---|---|---|
06/15/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0123-00296
Permit Description: SFR PANT2022 T22-M0073
Total Completed Inspections - 12
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2024 | COT - RSPL - Rough Soil | Passed | ||
01/30/2024 | COT - RSPL - Sewer | Passed | ||
01/30/2024 | COT - RSPL - Yard Water Line | Passed | ||
02/07/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
02/08/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
02/08/2024 | COT - RSBU - Preslab | Passed | ||
04/25/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
04/25/2024 | COT - RSBU - Roof Nailing | Passed | ||
05/15/2024 | COT - RSEL - Electrical Underground | Passed | ||
05/17/2024 | BULD - Electrical Clearance | Passed | ECO Clearance issued. | |
06/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
07/01/2024 | COT - RSBU - Interior Shear Bracing | Passed | Drywall is properly screwed per plans for the interior shear walls. Okay to proceed with tape, texture, and paint. |