Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Apply Date:
08/15/2023
Applicant:
Russ Salmon
Description:
LE23001 T22-M0058

Permit Reviews

Permit Number - TC-MDP-0123-00285
Permit Status: Inspections complete
Permit Description: LE23001 T22-M0058
Start Date Submittal Complete Date Status  
08/16/2023 RESIDENTIAL NEW DWELLING v.1 08/18/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0123-00285
Permit Status: Inspections complete
Permit Description: LE23001 T22-M0058
Total Outstanding Activity Conditions - 6
Date Name
07/10/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
08/16/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
08/16/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/16/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
08/17/2023 Post-Tension Inspection Report is required.
08/17/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0123-00285
Permit Status: Inspections complete
Permit Description: LE23001 T22-M0058
Date Description Comments
07/10/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/16/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00285
Permite Description: LE23001 T22-M0058
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
10/30/2023 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required Missing anchor bolts at garage shear wall, add shot pins to 2x6 sole plate at master shower, truss A03 at back of house missing rat runs and missing stud to carry load down to sole plate per truss calcs.
01/22/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Partial Pass Plumbing and electrical not per plans. Revise plans to show current electrical and plumbing work done and provide at final. Partial-pass. Ok to proceed at risk per supervisor Ernie Stevens.
04/22/2024 RSBU - Building Final N/A Re-inspection required Missing outlet receptacles in garage and refrigerator must run on its own circuit per E1 plans, missing cleanouts at bathrooms per P1 plans per Residential Intermediate inspection. Make proper corrections according to plans or revise plans showing current layout of electric and plumbing work done and provide updated city stamped plans at Final re-inspect.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00285
Permit Description: LE23001 T22-M0058
Total Completed Inspections - 24
Date Description Inspector Results Comments
09/28/2023 COT - RSPL - Rough Soil Passed
09/28/2023 COT - RSPL - Sewer Passed
09/28/2023 COT - RSPL - Yard Water Line Passed
10/10/2023 COT - RSEL - Electrical Underground Passed
10/10/2023 COT - RSBU - Preslab Passed
10/10/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
10/30/2023 COT - RSBU - Roof Nailing Passed
01/12/2024 COT - RSBU - Exterior Clips/Sheathing Passed
01/18/2024 RSBU - Building Progress Passed
01/18/2024 COT - RSEL - Grounding/Bonding Passed
01/18/2024 COT - RSPL - Gas Pressure Test Passed
01/18/2024 RSEL - Electrical Progress Passed
01/18/2024 RSME - Mechanical Progress Passed
01/18/2024 RSPL - Plumbing Progress Passed
01/31/2024 COT - RSBU - Interior Shear Bracing Passed Interior shear wall drywall is properly installed and secured to studs on a 7" spacing as called out on plans.
04/08/2024 BULD - Electrical Clearance Passed
04/12/2024 COT - BULD - SWG Clearance Passed
04/22/2024 ENGR Engineering Final Passed
04/22/2024 COT - RSEL - Outdoor Lighting Passed
04/22/2024 COT - RSME - Mechanical Final Passed
04/22/2024 COT - RSPL - Gas Final Passed
04/26/2024 RSBU - Building Final Passed
04/26/2024 COT - RSEL - Electrical Final Passed
04/26/2024 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LEC 21 OK TO PERMIT_V1.PDF DOCUMENTS VIEW
LEC 21 PERMIT APP_V1.PDF DOCUMENTS VIEW
LEC 21 SIC-2023-08-15_V1.PDF DOCUMENTS VIEW