Permit: TC-MDP-0123-00241
Permit Details
Apply Date:
06/27/2023
Applicant:
Russ Salmon
Description:
SFR LE23006 T22-M0054
Permit Reviews
Permit Number - TC-MDP-0123-00241
Permit Status: Inspections complete
Permit Description: SFR LE23006 T22-M0054
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/29/2023 | RESIDENTIAL NEW DWELLING v.1 | 07/04/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00241
Permit Status: Inspections complete
Permit Description: SFR LE23006 T22-M0054
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
06/29/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
06/29/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
06/29/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
07/03/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
07/10/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
07/10/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-0123-00241
Permit Status: Inspections complete
Permit Description: SFR LE23006 T22-M0054
Date | Description | Comments |
---|---|---|
06/29/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00241
Permite Description: SFR LE23006 T22-M0054
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/06/2023 | RSEL - Electrical Progress | N/A | Re-inspection required | 11/6/23: receptacle missing at kitchen countertop (per plans), seal top plate at entrance (gas going through top plate), seal chase at master, receptacle upstairs in bedroom facing west needs to be made up and wires secured, block all registers on three sides, refrigerant lines need to be brazed, block under upstairs loft, Up stairs bathroom flex duct not tied into register. |
11/06/2023 | RSME - Mechanical Progress | N/A | Re-inspection required | 11/6/23: receptacle missing at kitchen countertop (per plans), seal top plate at entrance (gas going through top plate), seal chase at master, receptacle upstairs in bedroom facing west needs to be made up and wires secured, block all registers on three sides, refrigerant lines need to be brazed, block under upstairs loft, Up stairs bathroom flex duct not tied into register. |
11/06/2023 | RSPL - Plumbing Progress | N/A | Re-inspection required | 11/6/23: receptacle missing at kitchen countertop (per plans), seal top plate at entrance (gas going through top plate), seal chase at master, receptacle upstairs in bedroom facing west needs to be made up and wires secured, block all registers on three sides, refrigerant lines need to be brazed, block under upstairs loft, Up stairs bathroom flex duct not tied into register. |
11/06/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00241
Permit Description: SFR LE23006 T22-M0054
Total Completed Inspections - 25