Permit: TC-MDP-0123-00223
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
7466 S CAMINO CARDAL
Address NEW:
7466 S CAMINO CARDAL
Apply Date:
09/25/2023
Applicant:
Russ Salmon
Description:
SFR LENNLE4003 T22-M0047
Permit Reviews
Permit Number - TC-MDP-0123-00223
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/26/2023 | RESIDENTIAL NEW DWELLING v.1 | 09/28/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00223
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 07/14/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 09/26/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 09/26/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 09/26/2023 | Post-Tension Inspection Report is required. |
| 09/26/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
| 09/26/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0123-00223
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
| Date | Description | Comments |
|---|---|---|
| 07/14/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 09/26/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00223
Permite Description: SFR LENNLE4003 T22-M0047
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/21/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 2-2x8 headers at front porch to be supported by 2-2x4 at each end, missing 2-2x10 with LUS26-2 hanger and 2-2x4 at stairs, 2x6 header at foyer not installed per detail S5.1 #6, beams supported by 2-2x6 studs and 4x6 post not installed per detail S5.1 #6. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00223
Permit Description: SFR LENNLE4003 T22-M0047
Total Completed Inspections - 21