Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0123-00223
Permit Details
Apply Date:
09/25/2023
Applicant:
Russ Salmon
Description:
SFR LENNLE4003 T22-M0047
Permit Reviews
Permit Number - TC-MDP-0123-00223
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/26/2023 | RESIDENTIAL NEW DWELLING v.1 | 09/28/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0123-00223
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
07/14/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
09/26/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
09/26/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
09/26/2023 | Post-Tension Inspection Report is required. |
09/26/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
09/26/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0123-00223
Permit Status: Inspections complete
Permit Description: SFR LENNLE4003 T22-M0047
Date | Description | Comments |
---|---|---|
07/14/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
09/26/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00223
Permite Description: SFR LENNLE4003 T22-M0047
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2023 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | 2-2x8 headers at front porch to be supported by 2-2x4 at each end, missing 2-2x10 with LUS26-2 hanger and 2-2x4 at stairs, 2x6 header at foyer not installed per detail S5.1 #6, beams supported by 2-2x6 studs and 4x6 post not installed per detail S5.1 #6. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0123-00223
Permit Description: SFR LENNLE4003 T22-M0047
Total Completed Inspections - 21