Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
12/15/2022
Applicant:
Russ Salmon
Description:
SFR LENNLE4005 T22-M0049

Permit Reviews

Permit Number - TC-MDP-0123-00198
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Start Date Submittal Complete Date Status  
01/31/2023 RESIDENTIAL NEW DWELLING v.1 02/03/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0123-00198
Permit Status: Issued
Permit Description: SFR LENNLE4005 T22-M0049
Total Outstanding Activity Conditions - 7
Date Name
02/01/2023 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
02/01/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
02/01/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
02/01/2023 Post-Tension Inspection Report is required.
02/01/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
07/18/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
07/18/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0123-00198
Permite Description: SFR LENNLE4005 T22-M0049
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
11/14/2023 RSBU - Building Final N/A Canceled Cancelled per Craig.
11/14/2023 COT - RSEL - Electrical Final N/A Canceled Cancelled per Craig.
11/14/2023 COT - RSME - Mechanical Final N/A Canceled Cancelled per Craig.
11/14/2023 COT - RSPL - Gas Final N/A Canceled Cancelled per Craig.
11/14/2023 COT - RSPL - Plumbing Final N/A Canceled Cancelled per Craig.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0123-00198
Permit Description: SFR LENNLE4005 T22-M0049
Total Completed Inspections - 20
Date Description Inspector Results Comments
04/19/2023 COT - RSPL - Yard Water Line Passed Water line is under 60# of air pressure. Okay to backfill trench.
04/21/2023 COT - RSPL - Rough Soil Passed 4/21/2023: Missing 2 way clean-out on underground plumbing at front of house
04/21/2023 COT - RSPL - Sewer Passed
04/26/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Rebar for shear wall clips are in place. Ufer ground rebar is in place. Post-tension cabling is in place with chairs. okay to pour concrete.
04/26/2023 COT - RSBU - Preslab Passed Okay to pour concrete.
04/26/2023 COT - RSEL - Electrical Underground Passed Conduit for kitchen island is in place.
04/26/2023 COT - RSEL - Grounding/Bonding Passed Ufer ground is in place.
05/26/2023 COT - RSBU - Roof Nailing Passed
05/26/2023 COT - RSBU - Exterior Clips/Sheathing Passed
05/26/2023 RSBU - Building Progress Passed
07/24/2023 COT - RSPL - Gas Pressure Test Passed
07/25/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
08/11/2023 COT - RSBU - Interior Shear Bracing Passed
09/18/2023 BULD - Electrical Clearance Passed ECO to TEP
11/06/2023 COT - BULD - SWG Clearance Passed 11/6/23:SWG clearance
11/16/2023 RSBU - Building Final Passed
11/16/2023 COT - RSEL - Electrical Final Passed
11/16/2023 COT - RSME - Mechanical Final Passed
11/16/2023 COT - RSPL - Gas Final Passed
11/16/2023 COT - RSPL - Plumbing Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LE2 68 4005 AR2_V1_V1.PDF DOCUMENTS VIEW
LE2-5, 68_4005 SIC-2023-01-25_V1-2023-01-31_V1.PDF DOCUMENTS VIEW