Permit: TC-COM-1224-02342
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
7170 E BROADWAY BL
Address NEW:
7170 E BROADWAY BL
Apply Date:
12/12/2024
Applicant:
David Smith
Description:
REPLACE THREE ROOFTOP PACKAGE HVAC UNITS WITH LIKE FOR LIKE EQUIPMENT. NO MODIFICATIONS REQUIRED.
Permit Reviews
Permit Number - TC-COM-1224-02342
Permit Status: Inspections
Permit Description: REPLACE THREE ROOFTOP PACKAGE HVAC UNITS WITH LIKE FOR LIKE EQUIPMENT. NO MODIFICATIONS REQUIRED.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/13/2024 | COMMERCIAL PDSD SIMPLE REVIEW v.1 | 12/14/2024 | REQUIRES RESUBMIT |
| 06/18/2025 | COMMERCIAL PDSD SIMPLE REVIEW v.2 | 06/18/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-1224-02342
Permit Status: Inspections
Permit Description: REPLACE THREE ROOFTOP PACKAGE HVAC UNITS WITH LIKE FOR LIKE EQUIPMENT. NO MODIFICATIONS REQUIRED.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/18/2025 | AIR BALANCING REPORT SHOWING THE TOTAL AIRFLOW AND THE OUTSIDE AIRFLOW OF EACH HEAT PUMP IS REQUIRED. |
Conditions
Permit Number - TC-COM-1224-02342
Permit Status: Inspections
Permit Description: REPLACE THREE ROOFTOP PACKAGE HVAC UNITS WITH LIKE FOR LIKE EQUIPMENT. NO MODIFICATIONS REQUIRED.
| Date | Description | Comments |
|---|---|---|
| 12/13/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-1224-02342
Permite Description: REPLACE THREE ROOFTOP PACKAGE HVAC UNITS WITH LIKE FOR LIKE EQUIPMENT. NO MODIFICATIONS REQUIRED.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/04/2025 | COT - LCME - Mechanical Intermediate | N/A | Re-inspection required | 8/4/25 1. Units are missing coil guards. 2. Units are missing appropriate electrical identification.Please label each unit on the rooftop with circuit number and the panel board that supplies power to unit.Also, label the circuit breakers in panels accordingly. 3. Customer does not have access to Thermostat. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-1224-02342
Permit Description: REPLACE THREE ROOFTOP PACKAGE HVAC UNITS WITH LIKE FOR LIKE EQUIPMENT. NO MODIFICATIONS REQUIRED.
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2025 | COT - LCME - Mechanical Final | Passed |