Permit: TC-COM-1223-02804
Permit Details
Apply Date:
12/08/2023
Applicant:
Description:
Parks and Recreation - permanent shade structure over the playground. (NO utilities such as electric on this permit) - RUDY GARCIA PARK
Permit Reviews
Permit Number - TC-COM-1223-02804
Permit Status: Needs resubmittal
Permit Description: Parks and Recreation - permanent shade structure over the playground. (NO utilities such as electric on this permit) - RUDY GARCIA PARK
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/27/2024 | COMMERCIAL REVIEW - FULL v.3 | 04/01/2024 | REQUIRES RESUBMIT |
03/12/2024 | COMMERCIAL REVIEW - FULL v.2 | 03/26/2024 | REQUIRES RESUBMIT |
11/04/2024 | COMMERCIAL REVIEW - FULL v.7 | 11/29/2024 | REQUIRES RESUBMIT |
12/05/2024 | COMMERCIAL REVIEW - FULL v.8 | 12/30/2024 | REQUIRES RESUBMIT |
12/11/2023 | COMMERCIAL REVIEW - FULL v.1 | 12/19/2023 | REQUIRES RESUBMIT |
04/09/2024 | COMMERCIAL REVIEW - FULL v.4 | 05/09/2024 | REQUIRES RESUBMIT |
08/28/2024 | COMMERCIAL REVIEW - FULL v.5 | 09/27/2024 | REQUIRES RESUBMIT |
10/07/2024 | COMMERCIAL REVIEW - FULL v.6 | 10/28/2024 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-1223-02804
Permit Status: Needs resubmittal
Permit Description: Parks and Recreation - permanent shade structure over the playground. (NO utilities such as electric on this permit) - RUDY GARCIA PARK
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
12/19/2023 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
12/19/2023 | SPECIAL INSPECTION FOR PILING, DRILLED PIERS AND CAISSONS IS REQUIRED. |
12/19/2023 | SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED. |
12/19/2023 | The following was not submitted. Awnings & canopies shall comply to the fire propagation performance criteria Test 1 or 2 of NFPA 701 and Flame Spread Index not greater than 25 per ASTM E84 or UL 723. IBC 3105.3 |
12/19/2023 | SPECIAL INSPECTION FOR WELDING IS REQUIRED. |