Permit: TC-COM-1124-02208
Permit Details
Apply Date:
11/15/2024
Applicant:
Cam Hemmen
Description:
THIS IS AN EXISTING RETAIL ESTABLISHMENT BEING REMODELED FOR A NEW TENANT WITH UPDATED EQUIPMENT, FIXTURES, AND FINISHES. EXTERIOR WORK INCLUDES ADDING A NEW DOUBLE DOOR AT THE BACK OF TENANT SPACE FOR MERCHANDISE LOADING AND DELIVERY. FIRE PROTECTIONS/SPRINKLER UPDATES TO BE BY CONTRACTOR UNDER A SEPARATE PERMIT. FIRE ALARM UPDATES TO BE BY CONTRACTOR UNDER A SEPARATE PERMIT. NEW SIGNAGE TO BE UNDER SEPARATE PERMIT.
Permit Reviews
Permit Number - TC-COM-1124-02208
Permit Status: Complete
Permit Description: THIS IS AN EXISTING RETAIL ESTABLISHMENT BEING REMODELED FOR A
NEW TENANT WITH UPDATED EQUIPMENT, FIXTURES, AND FINISHES.
EXTERIOR WORK INCLUDES ADDING A NEW DOUBLE DOOR AT THE BACK OF
TENANT SPACE FOR MERCHANDISE LOADING AND DELIVERY.
FIRE PROTECTIONS/SPRINKLER UPDATES TO BE BY CONTRACTOR UNDER A
SEPARATE PERMIT.
FIRE ALARM UPDATES TO BE BY CONTRACTOR UNDER A SEPARATE PERMIT.
NEW SIGNAGE TO BE UNDER SEPARATE PERMIT.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/04/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/10/2025 | APPROVED |
| 01/13/2025 | COMMERCIAL REVIEW - FULL v.2 | 01/21/2025 | APPROVED |
| 11/15/2024 | COMMERCIAL REVIEW - FULL v.1 | 12/10/2024 | REQUIRES RESUBMIT |
| 04/29/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/01/2025 | APPROVED |
| 01/21/2025 | RESTAMP - COMMERCIAL v.1 | 01/23/2025 | APPROVED |
Conditions
Permit Number - TC-COM-1124-02208
Permit Status: Complete
Permit Description: THIS IS AN EXISTING RETAIL ESTABLISHMENT BEING REMODELED FOR A
NEW TENANT WITH UPDATED EQUIPMENT, FIXTURES, AND FINISHES.
EXTERIOR WORK INCLUDES ADDING A NEW DOUBLE DOOR AT THE BACK OF
TENANT SPACE FOR MERCHANDISE LOADING AND DELIVERY.
FIRE PROTECTIONS/SPRINKLER UPDATES TO BE BY CONTRACTOR UNDER A
SEPARATE PERMIT.
FIRE ALARM UPDATES TO BE BY CONTRACTOR UNDER A SEPARATE PERMIT.
NEW SIGNAGE TO BE UNDER SEPARATE PERMIT.
| Date | Description | Comments |
|---|---|---|
| 01/15/2025 | AIR BALANCING REPORT IS REQUIRED. | |
| 01/15/2025 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. | |
| 01/15/2025 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. | |
| 01/15/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 11/15/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 01/15/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 11/15/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 01/15/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. | |
| 01/15/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-1124-02208
Permite Description: THIS IS AN EXISTING RETAIL ESTABLISHMENT BEING REMODELED FOR A
NEW TENANT WITH UPDATED EQUIPMENT, FIXTURES, AND FINISHES.
EXTERIOR WORK INCLUDES ADDING A NEW DOUBLE DOOR AT THE BACK OF
TENANT SPACE FOR MERCHANDISE LOADING AND DELIVERY.
FIRE PROTECTIONS/SPRINKLER UPDATES TO BE BY CONTRACTOR UNDER A
SEPARATE PERMIT.
FIRE ALARM UPDATES TO BE BY CONTRACTOR UNDER A SEPARATE PERMIT.
NEW SIGNAGE TO BE UNDER SEPARATE PERMIT.
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2025 | BULD - Electrical Clearance | N/A | Not Applicable | |
| 03/26/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 02/13/2025 | COT - HCBU - Building Progress | N/A | Partial Pass | 2-13-25, partial pass on above ceiling grid for IT room, storage areas. Grid not quite complete but contractor has another inspection for same next week. |
| 02/18/2025 | COT - HCME - Mechanical Progress | N/A | Partial Pass | 2-18-25, all duct work for IT room together with storage area installed. Okay to continue with construction. |
| 01/28/2025 | COT - HCPL - Plumbing Progress | N/A | Partial Pass | 1-28-25, verified plumbing under pressure. Okay to continue with construction remodel. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-1124-02208
Permit Description: THIS IS AN EXISTING RETAIL ESTABLISHMENT BEING REMODELED FOR A
NEW TENANT WITH UPDATED EQUIPMENT, FIXTURES, AND FINISHES.
EXTERIOR WORK INCLUDES ADDING A NEW DOUBLE DOOR AT THE BACK OF
TENANT SPACE FOR MERCHANDISE LOADING AND DELIVERY.
FIRE PROTECTIONS/SPRINKLER UPDATES TO BE BY CONTRACTOR UNDER A
SEPARATE PERMIT.
FIRE ALARM UPDATES TO BE BY CONTRACTOR UNDER A SEPARATE PERMIT.
NEW SIGNAGE TO BE UNDER SEPARATE PERMIT.
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/10/2025 | COT - HCBU - Framing | Passed | Rough framing is complete. Okay to one-side with drywall floor to bottom of roof trusses. | |
| 02/12/2025 | COT - HCME - Mechanical Above Ceiling | Passed | 2/12/25: Mechanical above ceiling in office and bathrooms is complete. Okay to install drywall hard lid ceiling in bathrooms and grid ceiling in office space. | |
| 03/25/2025 | ENGR Engineering Final | Passed | CO Ready, dumpster will be taken over by tenant. | |
| 03/25/2025 | COT - FCON - Fire - Final | Passed | ||
| 03/25/2025 | COT - HCEL - Electrical Final | Passed | ||
| 03/26/2025 | COT - HCBU - Building Above Ceiling | Passed | ||
| 03/26/2025 | COT - HCBU - Building Progress | Passed | ||
| 03/26/2025 | COT - HCBU - Preslab | Passed | ||
| 03/26/2025 | COT - HCEL - Electrical Above Ceiling | Passed | ||
| 03/26/2025 | COT - HCEL - Electrical Progress | Passed | ||
| 03/26/2025 | COT - HCME - Mechanical Progress | Passed | ||
| 03/26/2025 | COT - HCPL - Plumbing Above Ceiling | Passed | ||
| 03/26/2025 | COT - HCPL - Plumbing Progress | Passed | ||
| 04/22/2025 | COT - HCBU - Building Final | Passed | ||
| 04/22/2025 | COT - HCME - Mechanical Final | Passed | ||
| 04/22/2025 | COT - HCPL - Plumbing Final | Passed | ||
| 04/23/2025 | COT - HCBU - CofO | Passed | ||
| 04/28/2025 | TRSP - ROW - Final/Close-Out | Passed | Work performed on private property |