Permit Details

Status:
Complete
Type:
Commercial Building
Apply Date:
11/18/2023
Applicant:
Dave Collins
Description:
BLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building

Permit Reviews

Permit Number - TC-COM-1123-02690
Permit Status: Complete
Permit Description: BLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building
Start Date Submittal Complete Date Status  
01/17/2024 RESTAMP - COMMERCIAL v.1 01/19/2024 APPROVED Review Details
04/30/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 05/01/2024 REQUIRES RESUBMIT Review Details
11/21/2023 COMMERCIAL REVIEW - FULL v.1 12/18/2023 REQUIRES RESUBMIT Review Details
05/06/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.2 05/08/2024 APPROVED Review Details
04/19/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/23/2024 APPROVED Review Details
01/11/2024 COMMERCIAL REVIEW - FULL v.3 01/17/2024 APPROVED Review Details
01/24/2024 RESTAMP - COMMERCIAL v.1 02/06/2024 APPROVED Review Details
12/20/2023 COMMERCIAL REVIEW - FULL v.2 12/27/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-1123-02690
Permit Status: Complete
Permit Description: BLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building
Date Description Comments
11/21/2023 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
01/17/2024 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
01/17/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
11/21/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
01/17/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
01/17/2024 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
01/17/2024 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
01/17/2024 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
01/17/2024 Masonry Inspection Report submittal review is required.
01/17/2024 Racking Designs must be submitted and approved prior to final.
01/17/2024 Post-Installed Anchor Inspection Report is required.
01/17/2024 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
01/17/2024 SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED.
01/17/2024 SPECIAL INSPECTION FOR WELD REINF STEEL IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-1123-02690
Permite Description: BLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
02/22/2024 COT - HCBU - Framing N/A Partial Pass 2/16/24 partial for demising wall, ok to continue one side to ceiling and insulate need to verify fire seal at top deck
2/22/24: drywall nailing at demising wall west half per plan ok to insulate and proceed on east half.
03/18/2024 COT - HCPL - Plumbing Intermediate N/A Partial Pass 3/18/24: plumbing rough-in in rooms 101,102,103,104,105,106,107,108,109,110 passed.
04/22/2024 BULD - Electrical Clearance N/A Not Applicable
03/18/2024 COT - HCEL - Electrical Intermediate N/A Partial Pass 3/18/24: electrical in wall rough-in in rooms 101,102,103,104,105,106,107,108,109,110 passed.
04/22/2024 COT - HCBU - Building Above Ceiling N/A Re-inspection required 4/4/24 partial approval for above ceiling men's and women's restrooms OK to insulate and drywall
4/22/24: Mechanical above ceiling pending. Support on flex missing throughout, support at registers missing throughout, exhaust fan at IT/Storage not complete, transfer air grille not installed at IT/Storage (will check at final).
03/26/2024 COT - HCPL - Gas Final N/A Not Ready
04/25/2024 COT - HCPL - Plumbing Final N/A Re-inspection required 4/25/24: Water heater not installed per plans, Expansion tank at water heater obstructs the shutoff valve at water heater, Urinal at men's bathroom not installed, exhaust termination at roof not complete, refrigerant lines at roof need proper mechanical straps to hold electrical whip to refrigerant lines (zip ties are not allowed), rain caps required at refrigerant jacks at roof they must also be sealed, UV protect exterior piping, Mechanical not complete on roof,
04/25/2024 ENGR Engineering Final N/A Partial Pass This is a partial pass with a TCO4, we will not release full pass until it is decided on how to handle the issue with the remodeling of trash enclosure. Also environmental services will have to approve for the use of the 40yrd dumpster.
05/15/2024 COT - HCBU - Building Final N/A Not Ready 4/26/24: LEVEL 4 TCO
5/15/24: pending engineering final.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-1123-02690
Permit Description: BLDG 3 - a tenant finish for an existing one story single sided dock warehouse / distribution building
Total Completed Inspections - 23
Date Description Inspector Results Comments
02/09/2024 COT - HCPL - Rough Soil Passed 2/8/24: plumbing underground per plans ok to backfill.
02/09/2024 COT - HCEL - Electrical Underground Passed 2/9/24: electrical underground passed
03/14/2024 COT - HCBU - Preslab Passed
03/14/2024 COT - HCBU - Framing Passed 2/16/24 partial for demising wall, ok to continue one side to ceiling and insulate need to verify fire seal at top deck
2/22/24: drywall nailing at demising wall west half per plan ok to insulate and proceed on east half.
3/14/24: framing passed ok to proceed.
03/18/2024 COT - HCBU - Firewall/Fire Barrier/Firestop Passed
04/22/2024 COT - LCPL - Gas Pressure Test Passed
04/22/2024 COT - HCEL - Electrical Intermediate Passed
04/22/2024 COT - HCEL - Electrical Above Ceiling Passed
04/22/2024 COT - HCPL - Plumbing Above Ceiling Passed
04/23/2024 COT - HCBU - Building Above Ceiling Passed
04/25/2024 COT - HCEL - Electrical Final Passed
04/25/2024 TRSP - ROW - Final/Close-Out Passed
04/26/2024 COT - BULD - SWG Clearance Passed
04/25/2024 COT - HCME - Mechanical Above Ceiling Passed
04/25/2024 COT - HCME - Mechanical Intermediate Passed
04/25/2024 COT - HCPL - Gas Final Passed
04/25/2024 COT - FCON - Sprinkler - Final Passed
04/26/2024 COT - HCPL - Plumbing Final Passed
04/26/2024 COT - FCON - Alarm - Final Passed
04/26/2024 COT - FCON - Fire - Final Passed
04/30/2024 COT - HCME - Mechanical Final Passed
05/23/2024 ENGR Engineering Final Passed Dumpster enclosure modification approved by Andy Vera of Environmental Services. Note will be added to DP22-0149 that enclosure modification should be included on any future revision.
05/23/2024 COT - HCBU - Building Final Passed 4/26/24: LEVEL 4 TCO
5/15/24: pending engineering final.
5/23/24: ok for CofO

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
COFO_TEMPORARYCOFO.PDF DOCUMENTS VIEW
TC-COM-1123-02690 SPECIAL INSPECTION CERT- FINAL-2024-04-16_V1.PDF DOCUMENTS VIEW
21180 BLDG 3 KROSSWOOD PERMIT R3-2023-01-15_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
21180 BLDG 3 KROSSWOOD PERMIT R3-2023-01-15_V1.PDF DOCUMENTS VIEW
01_IECC ENERGY EVALUATION COMBINED_V2.PDF DOCUMENTS VIEW
02_2023-11-17 TUCSON CC 3 KROSSWOOD TI ROOF FRAMING REVIEW LETTER_V2.PDF DOCUMENTS VIEW