Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Commercial Building
Address:
3700 S 6TH AV
Apply Date:
11/02/2023
Applicant:
Logan Weitzel
Description:
Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop

Permit Reviews

Permit Number - TC-COM-1123-02577
Permit Status: Inspections
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Start Date Submittal Complete Date Status  
05/29/2024 COMMERCIAL REVIEW - FULL v.6 06/27/2024 REQUIRES RESUBMIT Review Details
08/19/2024 RESTAMP - COMMERCIAL v.1 08/21/2024 APPROVED Review Details
03/15/2024 COMMERCIAL REVIEW - FULL v.4 04/11/2024 REQUIRES RESUBMIT Review Details
02/05/2024 COMMERCIAL REVIEW - FULL v.2 02/05/2024 REQUIRES RESUBMIT Review Details
04/23/2024 COMMERCIAL REVIEW - FULL v.5 05/28/2024 REQUIRES RESUBMIT Review Details
02/06/2024 COMMERCIAL REVIEW - FULL v.3 03/07/2024 REQUIRES RESUBMIT Review Details
11/07/2023 COMMERCIAL REVIEW - FULL v.1 12/08/2023 REQUIRES RESUBMIT Review Details
07/19/2024 COMMERCIAL REVIEW - FULL v.7 08/19/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-1123-02577
Permit Status: Inspections
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Total Outstanding Activity Conditions - 4
Date Name
11/24/2023 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
11/24/2023 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
11/24/2023 SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED.
11/24/2023 SPECIAL INSPECTION FOR PILING, DRILLED PIERS AND CAISSONS IS REQUIRED.

Conditions

Permit Number - TC-COM-1123-02577
Permit Status: Inspections
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Date Description Comments
11/24/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-1123-02577
Permite Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
11/25/2024 BULD - Electrical Clearance N/A Not Applicable Service to site is current.
11/25/2024 COT - LCEL - Electrical Intermediate N/A Partial Pass Electric underground; conduits for 7 light poles. Ok to cover and asphalt progress areas.
12/11/2024 COT - LCBU - Building Final N/A Partial Pass 12/11/24: pending conditions.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-1123-02577
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Total Completed Inspections - 5
Date Description Inspector Results Comments
12/06/2024 COT - LCEL - Electrical Underground Passed
12/06/2024 COT - LCEL - Electrical Intermediate Passed
12/11/2024 COT - LCEL - Electrical Final Passed
12/11/2024 ENGR Engineering Final Passed Timer is set by an app on their phones.
12/11/2024 COT - LCEL - Outdoor Lighting Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-CONS-PLANS_V7.PDF DOCUMENTS VIEW
OUTDOOR LIGHTING INSPECTION CERTIFICATE-2024-07-18_V1.PDF DOCUMENTS VIEW