Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-1123-02577
Permit Details
Apply Date:
11/02/2023
Applicant:
Logan Weitzel
Description:
Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Permit Reviews
Permit Number - TC-COM-1123-02577
Permit Status: Inspections
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/29/2024 | COMMERCIAL REVIEW - FULL v.6 | 06/27/2024 | REQUIRES RESUBMIT |
08/19/2024 | RESTAMP - COMMERCIAL v.1 | 08/21/2024 | APPROVED |
03/15/2024 | COMMERCIAL REVIEW - FULL v.4 | 04/11/2024 | REQUIRES RESUBMIT |
02/05/2024 | COMMERCIAL REVIEW - FULL v.2 | 02/05/2024 | REQUIRES RESUBMIT |
04/23/2024 | COMMERCIAL REVIEW - FULL v.5 | 05/28/2024 | REQUIRES RESUBMIT |
02/06/2024 | COMMERCIAL REVIEW - FULL v.3 | 03/07/2024 | REQUIRES RESUBMIT |
11/07/2023 | COMMERCIAL REVIEW - FULL v.1 | 12/08/2023 | REQUIRES RESUBMIT |
07/19/2024 | COMMERCIAL REVIEW - FULL v.7 | 08/19/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-1123-02577
Permit Status: Inspections
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
11/24/2023 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
11/24/2023 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
11/24/2023 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
11/24/2023 | SPECIAL INSPECTION FOR PILING, DRILLED PIERS AND CAISSONS IS REQUIRED. |
Conditions
Permit Number - TC-COM-1123-02577
Permit Status: Inspections
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Date | Description | Comments |
---|---|---|
11/24/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-1123-02577
Permite Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/25/2024 | BULD - Electrical Clearance | N/A | Not Applicable | Service to site is current. |
11/25/2024 | COT - LCEL - Electrical Intermediate | N/A | Partial Pass | Electric underground; conduits for 7 light poles. Ok to cover and asphalt progress areas. |
12/11/2024 | COT - LCBU - Building Final | N/A | Partial Pass | 12/11/24: pending conditions. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-1123-02577
Permit Description: Addition of new site lighting at parking area and drive-thru for Starbucks coffee shop
Total Completed Inspections - 5
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2024 | COT - LCEL - Electrical Underground | Passed | ||
12/06/2024 | COT - LCEL - Electrical Intermediate | Passed | ||
12/11/2024 | COT - LCEL - Electrical Final | Passed | ||
12/11/2024 | ENGR Engineering Final | Passed | Timer is set by an app on their phones. | |
12/11/2024 | COT - LCEL - Outdoor Lighting | Passed |