Permit Details

Status:
Complete
Type:
Commercial Building
Address:
316 E 6TH ST
Address NEW:
316 E 6TH ST
Apply Date:
11/14/2022
Applicant:
Alexander Gallardo
Description:
Replacing 98 existing recirculating residential kitchen ventilation hoods with 98 ducted residential ventilation hoods.

Permit Reviews

Permit Number - TC-COM-1122-00111
Permit Status: Complete
Permit Description: Replacing 98 existing recirculating residential kitchen ventilation hoods with 98 ducted residential ventilation hoods.
Start Date Submittal Complete Date Status  
12/01/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/04/2023 APPROVED Review Details
05/03/2023 COMMERCIAL REVIEW - FULL v.1 06/08/2023 REQUIRES RESUBMIT Review Details
06/14/2023 COMMERCIAL REVIEW - FULL v.2 07/13/2023 APPROVED Review Details
12/08/2022 COMMERCIAL REVIEW - FULL v.1 02/03/2023 APPROVED Review Details

Conditions

Permit Number - TC-COM-1122-00111
Permit Status: Complete
Permit Description: Replacing 98 existing recirculating residential kitchen ventilation hoods with 98 ducted residential ventilation hoods.
Date Description Comments
01/10/2023 AIR BALANCING/COMMISSIONING REPORT IS REQUIRED.
02/03/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-1122-00111
Permite Description: Replacing 98 existing recirculating residential kitchen ventilation hoods with 98 ducted residential ventilation hoods.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
03/16/2023 COT - HCME - Mechanical Intermediate N/A Partial Pass Exhaust duct system (8”) for range/oven system. Rooms: 305, 304, 336, 334, 333, 327, 318, 314.
11/30/2023 BULD - Electrical Clearance N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-1122-00111
Permit Description: Replacing 98 existing recirculating residential kitchen ventilation hoods with 98 ducted residential ventilation hoods.
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/16/2023 COT - HCBU - Building Final Passed
08/16/2023 COT - HCME - Mechanical Final Passed
08/16/2023 COT - HCME - Mechanical Intermediate Passed
08/16/2023 COT - FCON - Fire - Final Passed
08/16/2023 COT - LCBU - Building Final Passed
11/30/2023 SITE - Zoning Final Passed Please note that 8 to 9 windows were seen to be within the 36” requirement for venting an exhaust hood next to an opening window.
11/30/2023 COT - BULD - SWG Clearance Passed