Permit: TC-COM-1025-01842
Permit Details
Status:
In Revision
Type:
Commercial Building
Address:
1651 E GLENN ST UNIT 119
Address NEW:
1651 E GLENN ST UNIT 119
Apply Date:
10/09/2025
Applicant:
Alfred Vega
Description:
REFURBISH DERBY APARTMENTS @ GLENN & ADELAIDE REV1: The revision is specific only to the Kitchen electrical based on field inspections conducted by the City of Tucson for the above noted units. On site inspections noted required changes to the electrical based on the previous approved permit set and the revised drawings updates Kitchen electrical to correct site location(s) and code requirements.
Permit Reviews
Permit Number - TC-COM-1025-01842
Permit Status: In revision
Permit Description: REFURBISH DERBY APARTMENTS @ GLENN & ADELAIDE
REV1: The revision is specific only to the Kitchen electrical based on field inspections conducted by the City of Tucson for the above noted units. On site inspections noted required changes to the electrical based on the previous approved permit set and the revised drawings updates Kitchen electrical to correct site location(s) and code requirements.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/26/2025 | COMMERCIAL REVIEW - FULL v.2 | 12/16/2025 | APPROVED |
| 10/09/2025 | COMMERCIAL REVIEW - FULL v.1 | 10/31/2025 | REQUIRES RESUBMIT |
| 04/30/2026 | COMMERCIAL REVIEW - FULL REVISION v.1 | N/A | IN REVIEW |
Conditions
Permit Number - TC-COM-1025-01842
Permit Status: In revision
Permit Description: REFURBISH DERBY APARTMENTS @ GLENN & ADELAIDE
REV1: The revision is specific only to the Kitchen electrical based on field inspections conducted by the City of Tucson for the above noted units. On site inspections noted required changes to the electrical based on the previous approved permit set and the revised drawings updates Kitchen electrical to correct site location(s) and code requirements.
| Date | Description | Comments |
|---|---|---|
| 10/09/2025 | Unit Numbers and their associated permit to be listed in the address section of the Master Plan located on Permit Number TC-COM-0725-01397 | |
| 10/10/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 10/09/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: In Revision
Permit Number: TC-COM-1025-01842
Permite Description: REFURBISH DERBY APARTMENTS @ GLENN & ADELAIDE
REV1: The revision is specific only to the Kitchen electrical based on field inspections conducted by the City of Tucson for the above noted units. On site inspections noted required changes to the electrical based on the previous approved permit set and the revised drawings updates Kitchen electrical to correct site location(s) and code requirements.
Total Outstanding Inspections - 12
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2025 | COT - BULD - SWG Clearance | N/A | Not Ready | |
| 12/23/2025 | COT - LCBU - Building Final | N/A | Not Ready | |
| 12/23/2025 | COT - LCEL - Electrical Final | N/A | Not Ready | |
| 12/23/2025 | COT - LCME - Mechanical Final | N/A | Not Ready | |
| 12/23/2025 | COT - LCPL - Plumbing Final | N/A | Not Ready | |
| 12/23/2025 | ENGR Engineering Final | N/A | Not Ready | Recall when complete and ready to occupy. |
| 12/23/2025 | COT - LCEL - Electrical Intermediate | N/A | Not Ready | |
| 12/23/2025 | COT - LCME - Mechanical Intermediate | N/A | Not Ready | |
| 12/23/2025 | COT - LCEL - Outdoor Lighting | N/A | Not Ready | |
| 12/23/2025 | COT - LCPL - Plumbing Intermediate | N/A | Not Ready | |
| 12/23/2025 | COT - LCPL - Rough Soil | N/A | Not Ready | |
| 01/22/2026 | BULD - Electrical Clearance | N/A | Re-inspection required | 1/22/26: Revision required for changes in conductor size at main panel and location of sub-panel must be appropriately identified on plan set, bond bushings required at raceway, conductors at panel must be protected from abrasion at raceway, EMT must be appropriately secured throughout, |
Completed Inspections
Permit Status: In Revision
Permit Number: TC-COM-1025-01842
Permit Description: REFURBISH DERBY APARTMENTS @ GLENN & ADELAIDE
REV1: The revision is specific only to the Kitchen electrical based on field inspections conducted by the City of Tucson for the above noted units. On site inspections noted required changes to the electrical based on the previous approved permit set and the revised drawings updates Kitchen electrical to correct site location(s) and code requirements.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/23/2025 | COT - FCON - Fire - Final | Passed | ||
| 12/23/2025 | TRSP - ROW - Final/Close-Out | Passed |