Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-1024-01953
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
8815 E GOLF LINKS RD
Address NEW:
8815 E GOLF LINKS RD
Apply Date:
10/10/2024
Applicant:
Bruce Call
Description:
This is for a retaining wall to facilitate additional parking in conjunction with Radiant Gymnastics Phase 2 building. Ref: TP-MOD-1024-000011 and DP18-0082 and TC-COM-1123-02689
Permit Reviews
Permit Number - TC-COM-1024-01953
Permit Status: Inspections
Permit Description: This is for a retaining wall to facilitate additional parking in conjunction with Radiant Gymnastics Phase 2 building. Ref: TP-MOD-1024-000011 and DP18-0082 and TC-COM-1123-02689
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/02/2025 | COMMERCIAL FENCE/WALL v.3 | 05/21/2025 | APPROVED |
| 10/14/2024 | COMMERCIAL FENCE/WALL v.1 | 11/01/2024 | REQUIRES RESUBMIT |
| 05/21/2025 | RESTAMP - COMMERCIAL v.1 | 05/23/2025 | APPROVED |
| 03/20/2025 | COMMERCIAL FENCE/WALL v.2 | 04/04/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-1024-01953
Permit Status: Inspections
Permit Description: This is for a retaining wall to facilitate additional parking in conjunction with Radiant Gymnastics Phase 2 building. Ref: TP-MOD-1024-000011 and DP18-0082 and TC-COM-1123-02689
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 10/25/2024 | SPECIAL INSPECTION FOR CONCRETE FOOTINGS IS REQUIRED. |
| 10/25/2024 | SPECIAL INSPECTION FOR MASONRY IS REQUIRED. |
Conditions
Permit Number - TC-COM-1024-01953
Permit Status: Inspections
Permit Description: This is for a retaining wall to facilitate additional parking in conjunction with Radiant Gymnastics Phase 2 building. Ref: TP-MOD-1024-000011 and DP18-0082 and TC-COM-1123-02689
| Date | Description | Comments |
|---|---|---|
| 05/23/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-1024-01953
Permite Description: This is for a retaining wall to facilitate additional parking in conjunction with Radiant Gymnastics Phase 2 building. Ref: TP-MOD-1024-000011 and DP18-0082 and TC-COM-1123-02689
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2025 | COT - LCBU - Masonry Pregrout | N/A | Re-inspection required | 7/28/25 1. Missed footing inspection, please provide pictures of footing depth and reinforcements. 2. North West wall (SK1) is at max height, appears like you may be adding another lift. |
| 08/13/2025 | COT - LCBU - Stem Wall/Retaining Wall | N/A | Partial Pass | Retaining wall at North-East of property is grouted to finished height, okay to cap. |