Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-1024-01945
Permit Details
Apply Date:
10/09/2024
Applicant:
jerry huckabee
Description:
INTERIOR ALTERATIONS TO UNIT 240, 4500 N. ORACLE ROAD TUCSON, AZ. 85705 TO INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A SEPARATE PERMIT: -FIRE SPRINKLER ALTERATIONS -FIRE ALARM -SIGNAGE THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A DEFERRED SUBMITTAL: -MOBILE MEDIA RACKING
Permit Reviews
Permit Number - TC-COM-1024-01945
Permit Status: Inspections
Permit Description: INTERIOR ALTERATIONS TO UNIT 240, 4500 N. ORACLE ROAD TUCSON, AZ. 85705 TO INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A SEPARATE PERMIT: -FIRE SPRINKLER ALTERATIONS -FIRE ALARM -SIGNAGE THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A DEFERRED SUBMITTAL: -MOBILE MEDIA RACKING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/13/2024 | RESTAMP - COMMERCIAL v.1 | 12/18/2024 | APPROVED |
12/03/2024 | COMMERCIAL REVIEW - FULL v.2 | 12/03/2024 | REQUIRES RESUBMIT |
10/14/2024 | COMMERCIAL REVIEW - FULL v.1 | 11/19/2024 | REQUIRES RESUBMIT |
01/27/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 01/30/2025 | APPROVED |
12/10/2024 | COMMERCIAL REVIEW - FULL v.3 | 12/13/2024 | APPROVED |
01/23/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 01/27/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-1024-01945
Permit Status: Inspections
Permit Description: INTERIOR ALTERATIONS TO UNIT 240, 4500 N. ORACLE ROAD TUCSON, AZ. 85705 TO INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A SEPARATE PERMIT: -FIRE SPRINKLER ALTERATIONS -FIRE ALARM -SIGNAGE THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A DEFERRED SUBMITTAL: -MOBILE MEDIA RACKING
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
12/13/2024 | AIR BALANCING REPORT IS REQUIRED. |
12/13/2024 | Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents. |
12/13/2024 | Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents. |
12/13/2024 | Post-Installed Anchor Inspection Report is required. |
12/13/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-1024-01945
Permit Status: Inspections
Permit Description: INTERIOR ALTERATIONS TO UNIT 240, 4500 N. ORACLE ROAD TUCSON, AZ. 85705 TO INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A SEPARATE PERMIT: -FIRE SPRINKLER ALTERATIONS -FIRE ALARM -SIGNAGE THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A DEFERRED SUBMITTAL: -MOBILE MEDIA RACKING
Date | Description | Comments |
---|---|---|
01/09/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
12/10/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
01/09/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
12/13/2024 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-1024-01945
Permite Description: INTERIOR ALTERATIONS TO UNIT 240, 4500 N. ORACLE ROAD TUCSON, AZ. 85705 TO INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A SEPARATE PERMIT: -FIRE SPRINKLER ALTERATIONS -FIRE ALARM -SIGNAGE THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A DEFERRED SUBMITTAL: -MOBILE MEDIA RACKING
Total Outstanding Inspections - 3
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/11/2025 | COT - HCME - Mechanical Progress | N/A | Partial Pass | |
02/20/2025 | COT - HCBU - Framing | N/A | Partial Pass | |
02/26/2025 | COT - HCEL - Electrical Progress | N/A | Partial Pass |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-1024-01945
Permit Description: INTERIOR ALTERATIONS TO UNIT 240, 4500 N. ORACLE ROAD TUCSON, AZ. 85705 TO INCLUDE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A SEPARATE PERMIT: -FIRE SPRINKLER ALTERATIONS -FIRE ALARM -SIGNAGE THE FOLLOWING SCOPE OF WORK WILL BE ISSUED AS A DEFERRED SUBMITTAL: -MOBILE MEDIA RACKING
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/31/2025 | COT - HCPL - Plumbing Progress | Passed |