Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Address:
1890 W GRANT RD
Address NEW:
1890 W GRANT RD
Apply Date:
10/01/2024
Applicant:
Daniel Simmons
Description:
REPAIRING A WIND DAMAGED ROOF. ROOF MEMBRANE WAS BLOWN OFF AND RIPPED THE TOP FLANGE OF TWO(2) TJI JOISTS. PLYWOOD SHEATHING WILL BE REPLACED IN AREAS WHERE IT WAS LIFTED/SHIFTED AND THE MEMBRANE WILL BE FIXED. THIS SUBMITTAL ALSO ADDRESSES CODE VIOLATION CE-VIO0624-02203 STATING ELECTRICAL WIRES WERE EXPOSED. THESE WILL BE REPLACED LIKE FOR LIKE.

Permit Reviews

Permit Number - TC-COM-1024-01906
Permit Status: Complete
Permit Description: REPAIRING A WIND DAMAGED ROOF. ROOF MEMBRANE WAS BLOWN OFF AND RIPPED THE TOP FLANGE OF TWO(2) TJI JOISTS. PLYWOOD SHEATHING WILL BE REPLACED IN AREAS WHERE IT WAS LIFTED/SHIFTED AND THE MEMBRANE WILL BE FIXED. THIS SUBMITTAL ALSO ADDRESSES CODE VIOLATION CE-VIO0624-02203 STATING ELECTRICAL WIRES WERE EXPOSED. THESE WILL BE REPLACED LIKE FOR LIKE.
Start Date Submittal Complete Date Status  
11/21/2024 RESTAMP - COMMERCIAL v.1 12/02/2024 APPROVED Review Details
06/26/2026 SPECIAL INSPECTION REVIEW v.2 06/30/2026 APPROVED Review Details
03/18/2026 SPECIAL INSPECTION REVIEW v.1 03/18/2026 REQUIRES RESUBMIT Review Details
10/07/2024 COMMERCIAL REVIEW - FULL v.1 11/06/2024 REQUIRES RESUBMIT Review Details
11/07/2024 COMMERCIAL REVIEW - FULL v.2 11/21/2024 APPROVED Review Details
01/29/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/29/2025 APPROVED Review Details

Conditions

Permit Number - TC-COM-1024-01906
Permit Status: Complete
Permit Description: REPAIRING A WIND DAMAGED ROOF. ROOF MEMBRANE WAS BLOWN OFF AND RIPPED THE TOP FLANGE OF TWO(2) TJI JOISTS. PLYWOOD SHEATHING WILL BE REPLACED IN AREAS WHERE IT WAS LIFTED/SHIFTED AND THE MEMBRANE WILL BE FIXED. THIS SUBMITTAL ALSO ADDRESSES CODE VIOLATION CE-VIO0624-02203 STATING ELECTRICAL WIRES WERE EXPOSED. THESE WILL BE REPLACED LIKE FOR LIKE.
Date Description Comments
10/07/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
11/01/2024 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.
11/01/2024 TJI JOISTS WHICH MAY HAVE BEEN DAMAGED IN THE WIND UPLIFT EVENT SHALL BE INSPECTED TO VERIFY THE WEBS ARE FULLY CONNECTED TO THE TOP CHORD AT THE WEST WALL.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-1024-01906
Permite Description: REPAIRING A WIND DAMAGED ROOF. ROOF MEMBRANE WAS BLOWN OFF AND RIPPED THE TOP FLANGE OF TWO(2) TJI JOISTS. PLYWOOD SHEATHING WILL BE REPLACED IN AREAS WHERE IT WAS LIFTED/SHIFTED AND THE MEMBRANE WILL BE FIXED. THIS SUBMITTAL ALSO ADDRESSES CODE VIOLATION CE-VIO0624-02203 STATING ELECTRICAL WIRES WERE EXPOSED. THESE WILL BE REPLACED LIKE FOR LIKE.
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
02/03/2025 COT - LCEL - Electrical Final N/A Not Ready
02/03/2025 COT - HCBU - TCO N/A Not Applicable
02/03/2025 COT - FCON - Fire - Final N/A Re-inspection required I tried to call the contact info on the permit and I was not able to get anyone on the line.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-1024-01906
Permit Description: REPAIRING A WIND DAMAGED ROOF. ROOF MEMBRANE WAS BLOWN OFF AND RIPPED THE TOP FLANGE OF TWO(2) TJI JOISTS. PLYWOOD SHEATHING WILL BE REPLACED IN AREAS WHERE IT WAS LIFTED/SHIFTED AND THE MEMBRANE WILL BE FIXED. THIS SUBMITTAL ALSO ADDRESSES CODE VIOLATION CE-VIO0624-02203 STATING ELECTRICAL WIRES WERE EXPOSED. THESE WILL BE REPLACED LIKE FOR LIKE.
Total Completed Inspections - 7
Date Description Inspector Results Comments
02/03/2025 ENGR Engineering Final Passed
02/03/2025 COT - LCBU - Framing Passed
02/03/2025 COT - LCEL - Electrical Above Ceiling Passed
02/03/2025 COT - LCBU - Roof Nailing Passed
02/10/2025 BULD - Electrical Clearance Passed RECN
02/10/2025 COT - BULD - SWG Clearance Passed
02/10/2025 COT - LCBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL (SSRS).PDF DOCUMENTS VIEW
LOFC_LETTEROFCOMPLETION (SSRS).PDF DOCUMENTS VIEW
PERMIT TC-COM-1024-01906 _ FINAL-2026-06-24_V1.PDF DOCUMENTS VIEW
1890 GRANT ROAD SI CERTIFICATE-2025-01-17_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2_DRAWINGS_ROSS INDUSTRIES_V2.PDF DOCUMENTS VIEW