Permit Details

Status:
Issued
Type:
Commercial Building
Apply Date:
10/06/2023
Applicant:
Alan Harman
Description:
Remodel for new kitchen for In need community meal delivery (Building 3)

Permit Reviews

Permit Number - TC-COM-1023-02356
Permit Status: Issued
Permit Description: Remodel for new kitchen for In need community meal delivery (Building 3)
Start Date Submittal Complete Date Status  
11/29/2023 COMMERCIAL REVIEW - FULL v.3 11/30/2023 REQUIRES RESUBMIT Review Details
01/05/2024 COMMERCIAL REVIEW - FULL v.4 01/09/2024 REQUIRES RESUBMIT Review Details
11/16/2023 COMMERCIAL REVIEW - FULL v.2 11/20/2023 REQUIRES RESUBMIT Review Details
01/09/2024 COMMERCIAL REVIEW - FULL v.5 01/16/2024 APPROVED Review Details
03/27/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/01/2024 APPROVED Review Details
01/24/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/25/2024 APPROVED Review Details
10/09/2023 COMMERCIAL REVIEW - FULL v.1 11/02/2023 REQUIRES RESUBMIT Review Details
01/16/2024 RESTAMP - COMMERCIAL v.1 01/17/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-1023-02356
Permit Status: Issued
Permit Description: Remodel for new kitchen for In need community meal delivery (Building 3)
Total Outstanding Activity Conditions - 2
Date Name
01/17/2024 AIR BALANCING & HOOD PERFORMANCE REPORT IS REQUIRED.
01/17/2024 WATER STERILIZATION REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-1023-02356
Permit Status: Issued
Permit Description: Remodel for new kitchen for In need community meal delivery (Building 3)
Date Description Comments
01/17/2024 Separate submittal to PC RWRD Industrial Wastewater Control is required . Contact Lucinda.Hyatt@pima.gov for review and assessment.
01/17/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-1023-02356
Permite Description: Remodel for new kitchen for In need community meal delivery (Building 3)
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
09/10/2024 COT - HCEL - Electrical Intermediate N/A Partial Pass 9/10/24: Electrical in wall passed ok to proceed.
10/04/2024 COT - HCME - Kitchen Hood N/A Partial Pass Smoke test complete on hood ductwork OK to install insulation and wrap and clamps on captive air duct
10/04/2024 COT - HCME - Mechanical Intermediate N/A Not Ready Call for kitchen hood duct smoke test
10/04/2024 COT - HCPL - Plumbing Intermediate N/A Not Ready Call for inspection of kitchen hood duct smoke test
COT - FCON - Fire - Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-1023-02356
Permit Description: Remodel for new kitchen for In need community meal delivery (Building 3)
Total Completed Inspections - 5
Date Description Inspector Results Comments
08/15/2024 COT - HCPL - Rough Soil Passed
08/15/2024 COT - HCBU - Preslab Passed
08/28/2024 COT - HCBU - Framing Passed
10/16/2024 ENGR Engineering Final Passed
10/16/2024 TRSP - ROW - Final/Close-Out Passed

Documents

File Name Document Type  
COT APPROVAL GREASE INTERCEPTER - GAP MINISTRIES_V1.PDF DOCUMENTS VIEW
CONS-5_A-1 THRU H-1 GAP MINISTRIES KITCHEN FLOOR PLAN 1-03-24_D4_V5.PDF DOCUMENTS VIEW