Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0923-02246
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
5075 E VALENCIA RD
Address NEW:
5075 E VALENCIA RD
Apply Date:
09/20/2023
Applicant:
Geoff Sylvester
Description:
THE PROPOSED PROJECT IS FOR A NEW SELF-SERVICE DRIVE THRU CAR WASH FACILITY AND EXTERIOR VACUUM ARCHES AT DEDICATED PARKING SPACES. THE BUILDING HAS BEEN DESIGNED TO CONTAIN ALL CAR WASHING AND VACUUM MOTOR EQUIPMENT INSIDE TO MITIGATE VISUAL AND NOISE IMPACTS.
Permit Reviews
Permit Number - TC-COM-0923-02246
Permit Status: Issued
Permit Description: THE PROPOSED PROJECT IS FOR A NEW SELF-SERVICE DRIVE THRU CAR WASH FACILITY AND EXTERIOR VACUUM ARCHES AT DEDICATED PARKING SPACES. THE BUILDING HAS BEEN DESIGNED TO CONTAIN ALL CAR WASHING AND VACUUM MOTOR EQUIPMENT INSIDE TO MITIGATE VISUAL AND NOISE IMPACTS.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/13/2024 | RESTAMP - COMMERCIAL v.3 | 03/19/2024 | REQUIRES RESUBMIT |
| 03/26/2024 | RESTAMP - COMMERCIAL v.1 | 03/28/2024 | APPROVED |
| 02/03/2025 | COMMERCIAL REVIEW - FULL v.3 | 03/03/2025 | APPROVED |
| 09/21/2023 | COMMERCIAL REVIEW - FULL v.1 | 09/21/2023 | REQUIRES RESUBMIT |
| 02/27/2024 | COMMERCIAL REVIEW - FULL v.4 | 02/29/2024 | APPROVED |
| 03/03/2025 | RESTAMP - COMMERCIAL v.1 | 03/05/2025 | APPROVED |
| 01/11/2024 | COMMERCIAL REVIEW - FULL v.3 | 02/08/2024 | REQUIRES RESUBMIT |
| 01/03/2025 | COMMERCIAL REVIEW - FULL v.2 | 01/24/2025 | REQUIRES RESUBMIT |
| 03/22/2024 | RESTAMP - COMMERCIAL v.4 | 03/26/2024 | APPROVED |
| 03/07/2024 | RESTAMP - COMMERCIAL v.2 | 03/13/2024 | REQUIRES RESUBMIT |
| 09/22/2023 | COMMERCIAL REVIEW - FULL v.2 | 10/24/2023 | REQUIRES RESUBMIT |
| 12/31/2024 | COMMERCIAL REVIEW - FULL v.1 | 01/03/2025 | REQUIRES RESUBMIT |
| 08/15/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 09/05/2025 | APPROVED |
| 02/29/2024 | RESTAMP - COMMERCIAL v.1 | 03/06/2024 | REQUIRES RESUBMIT |
| 10/13/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 11/04/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0923-02246
Permit Status: Issued
Permit Description: THE PROPOSED PROJECT IS FOR A NEW SELF-SERVICE DRIVE THRU CAR WASH FACILITY AND EXTERIOR VACUUM ARCHES AT DEDICATED PARKING SPACES. THE BUILDING HAS BEEN DESIGNED TO CONTAIN ALL CAR WASHING AND VACUUM MOTOR EQUIPMENT INSIDE TO MITIGATE VISUAL AND NOISE IMPACTS.
Total Outstanding Activity Conditions - 9
| Date | Name |
|---|---|
| 03/26/2024 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
| 03/26/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 03/26/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 03/26/2024 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
| 03/26/2024 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
| 03/26/2024 | SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED. |
| 03/26/2024 | Masonry Inspection Report submittal review is required. |
| 03/26/2024 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 11/18/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Conditions
Permit Number - TC-COM-0923-02246
Permit Status: Issued
Permit Description: THE PROPOSED PROJECT IS FOR A NEW SELF-SERVICE DRIVE THRU CAR WASH FACILITY AND EXTERIOR VACUUM ARCHES AT DEDICATED PARKING SPACES. THE BUILDING HAS BEEN DESIGNED TO CONTAIN ALL CAR WASHING AND VACUUM MOTOR EQUIPMENT INSIDE TO MITIGATE VISUAL AND NOISE IMPACTS.
| Date | Description | Comments |
|---|---|---|
| 09/21/2023 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 09/21/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 09/21/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0923-02246
Permite Description: THE PROPOSED PROJECT IS FOR A NEW SELF-SERVICE DRIVE THRU CAR WASH FACILITY AND EXTERIOR VACUUM ARCHES AT DEDICATED PARKING SPACES. THE BUILDING HAS BEEN DESIGNED TO CONTAIN ALL CAR WASHING AND VACUUM MOTOR EQUIPMENT INSIDE TO MITIGATE VISUAL AND NOISE IMPACTS.
Total Outstanding Inspections - 10
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2025 | COT - HCPL - Sewer | N/A | Partial Pass | 8-8-25: verified 6" SDR35 PVC sewer line and tracer wire-Okay to backfill open trench of approximately 25'. Air test will be performed at a later date. |
| 08/18/2025 | COT - HCPL - Yard Water Line | N/A | Not Ready | 8-18-25: not ready |
| 09/10/2025 | COT - HCEL - Electrical Underground | N/A | Partial Pass | 9-10-25: verified in excess of 30 primary & secondary Schedule 40 electrical conduits ranging from 1-4" in size throughout site. These conduits are intended for SES, panels, motor controllers. An actual count of conduits will be taken prior concrete placement. Okay to continue with construction at progress areas. |
| 09/12/2025 | COT - HCEL - Electrical Progress | N/A | Partial Pass | 9/12/25: electrical underground at building slab approved ok to proceed |
| 08/29/2025 | COT - HCPL - Rough Soil | N/A | Not Ready | |
| 11/18/2025 | COT - HCPL - Plumbing Progress | N/A | Partial Pass | 11-18-25: in wall plumbing rough in at bathroom & office verified per plan. Add rubber/plastic bushings where DWV rubs against metal framing at notched locations. Okay to continue with construction and will verify bushings at upcoming inspection. |
| 11/20/2025 | COT - HCBU - Building Above Ceiling | N/A | Partial Pass | 11-20-25: verified above ceiling MVD'S in equipment room together with the intake for the ceiling mount for A/C located at the office. All are properly secured to the roof deck. Okay to continue with construction at progress areas. |
| 10/28/2025 | COT - HCBU - Building Progress | N/A | Canceled | |
| 12/01/2025 | COT - HCBU - Framing | N/A | Partial Pass | 12-1-25: verified steel beams for exhausts in equipment room. Okay to continue with construction at progress areas. |
| 12/01/2025 | COT - HCME - Mechanical Above Ceiling | N/A | Partial Pass | 12-1-25: exhausts in equipment room and fan in office verified per plans. Okay to continue with construction at progress areas. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0923-02246
Permit Description: THE PROPOSED PROJECT IS FOR A NEW SELF-SERVICE DRIVE THRU CAR WASH FACILITY AND EXTERIOR VACUUM ARCHES AT DEDICATED PARKING SPACES. THE BUILDING HAS BEEN DESIGNED TO CONTAIN ALL CAR WASHING AND VACUUM MOTOR EQUIPMENT INSIDE TO MITIGATE VISUAL AND NOISE IMPACTS.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/07/2025 | PDSD Building Division Pre-Construction Meeting | Passed | ||
| 08/11/2025 | COT - HCPL - Sewer | Passed | 8-11-25: sewer pressure test at 4 psi approved. Okay to continue with construction. | |
| 09/25/2025 | COT - HCBU - Masonry Pregrout | Passed | 9.25.25 1st lift approved, proceed |
|
| 10/21/2025 | COT - HCBU - Excavation/Rebar/Zoning | Passed | Passed 10/21/25 |