Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Commercial Building
Apply Date:
08/22/2024
Applicant:
Abraham Flores
Description:
This Application for Building B 4 units (3,376SF) This Building is Related to Master plan Application Code: TCD-COM-0724-01340 It is an Apartment complex, made up of 3 buildings. Building A - 5 units Building B - 4 units (3,376SF) Building C - 3Units

Permit Reviews

Permit Number - TC-COM-0824-01642
Permit Status: Issued
Permit Description: This Application for Building B 4 units (3,376SF) This Building is Related to Master plan Application Code: TCD-COM-0724-01340 It is an Apartment complex, made up of 3 buildings. Building A - 5 units Building B - 4 units (3,376SF) Building C - 3Units
Start Date Submittal Complete Date Status  
08/27/2024 COMMERCIAL REVIEW - FULL v.1 09/26/2024 REQUIRES RESUBMIT Review Details
04/02/2025 COMMERCIAL REVIEW - FULL v.3 04/02/2025 REQUIRES RESUBMIT Review Details
04/17/2025 RESTAMP - COMMERCIAL v.1 04/21/2025 APPROVED Review Details
04/24/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/28/2025 APPROVED Review Details
01/15/2025 COMMERCIAL REVIEW - FULL v.2 02/04/2025 REQUIRES RESUBMIT Review Details
04/03/2025 COMMERCIAL REVIEW - FULL v.4 04/17/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0824-01642
Permit Status: Issued
Permit Description: This Application for Building B 4 units (3,376SF) This Building is Related to Master plan Application Code: TCD-COM-0724-01340 It is an Apartment complex, made up of 3 buildings. Building A - 5 units Building B - 4 units (3,376SF) Building C - 3Units
Total Outstanding Activity Conditions - 10
Date Name
04/07/2025 AIR BALANCING REPORT IS REQUIRED.
04/07/2025 Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents.
04/07/2025 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
04/07/2025 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
04/07/2025 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
04/07/2025 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
04/07/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
04/07/2025 WATER STERILIZATION REPORT IS REQUIRED.
04/07/2025 SPECIAL INSPECTION FOR WELD REINF STEEL IS REQUIRED.
04/07/2025 SPECIAL INSPECTION FOR WELDING IS REQUIRED.

Conditions

Permit Number - TC-COM-0824-01642
Permit Status: Issued
Permit Description: This Application for Building B 4 units (3,376SF) This Building is Related to Master plan Application Code: TCD-COM-0724-01340 It is an Apartment complex, made up of 3 buildings. Building A - 5 units Building B - 4 units (3,376SF) Building C - 3Units
Date Description Comments
08/26/2024 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
08/26/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
08/26/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
04/07/2025 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-0824-01642
Permite Description: This Application for Building B 4 units (3,376SF) This Building is Related to Master plan Application Code: TCD-COM-0724-01340 It is an Apartment complex, made up of 3 buildings. Building A - 5 units Building B - 4 units (3,376SF) Building C - 3Units
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
05/01/2025 COT - HCBU - Excavation/Rebar/Zoning N/A Partial Pass Buildings “B” and “C” stem wall footings, Ok to,place,concrete in progress areas. NOTE: A job site is required; please post on Sahuaro Street side.
09/25/2025 COT - HCBU - Exterior Clips/Sheathing N/A Partial Pass Exterior clips/sheathing complete. Ok to cover exterior walls.
01/27/2026 COT - HCBU - Building Progress N/A Partial Pass
02/04/2026 COT - HCPL - Plumbing Roof Drains N/A Not Ready
02/18/2026 COT - HCEL - Electrical Intermediate N/A Not Ready
02/18/2026 COT - HCME - Mechanical Intermediate N/A Not Ready
02/18/2026 COT - HCPL - Plumbing Intermediate N/A Not Ready
05/13/2026 COT - HCPL - Yard Water Line N/A Partial Pass 5/13/26: Main water line per approved plans, system under pressure and shading was present at time of inspection. Ok to proceed with backfill. Ensure additional backfill material is used to backfill trench

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-0824-01642
Permit Description: This Application for Building B 4 units (3,376SF) This Building is Related to Master plan Application Code: TCD-COM-0724-01340 It is an Apartment complex, made up of 3 buildings. Building A - 5 units Building B - 4 units (3,376SF) Building C - 3Units
Total Completed Inspections - 4
Date Description Inspector Results Comments
06/13/2025 COT - HCPL - Rough Soil Passed
06/25/2025 COT - HCBU - Preslab Passed Ok to place concrete in progress areas. Ensure slab ares are properly termite treated.
09/25/2025 COT - HCBU - Roof Nailing Passed OK to,dry-in roof system
03/23/2026 COT - HCPL - Sewer Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
365-BUILDING B-2025-04-23_V1.PDF DOCUMENTS VIEW
CONS-CONS-REV1_1_PLAN SET_BUILDING B_V2_V3_V3.PDF DOCUMENTS VIEW
REV1_1_STRUCTURAL_BUILDING B_V2_V3_V3.PDF DOCUMENTS VIEW