Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Commercial Building
Address NEW:
5462 E GLENN ST BLDG 1
Apply Date:
07/11/2025
Applicant:
Ashley Benjamin
Description:
Restricted Record - New Medical Office Building on existing lot - North Building

Permit Reviews

Permit Number - TC-COM-0725-01348
Permit Status: Inspections
Permit Description: Restricted Record - New Medical Office Building on existing lot - North Building
Start Date Submittal Complete Date Status  
07/15/2025 COMMERCIAL REVIEW - FULL v.1 08/06/2025 REQUIRES RESUBMIT Review Details
08/21/2025 COMMERCIAL REVIEW - FULL v.2 09/17/2025 APPROVED Review Details
09/17/2025 RESTAMP - COMMERCIAL v.1 09/22/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0725-01348
Permit Status: Inspections
Permit Description: Restricted Record - New Medical Office Building on existing lot - North Building
Total Outstanding Activity Conditions - 20
Date Name
07/25/2025 Applies to All: Deferred submittal documents must be submitted and approved prior to installation of construction elements included in deferred submittal documents.
07/25/2025 Special inspections must be performed by an approved third party inspection agency at the owner's expense. Special inspection forms and reports are required to be submitted for review and approved prior to issuance of final approval documents.
07/25/2025 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
07/25/2025 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
07/25/2025 COUNTY HEALTH INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED.
07/25/2025 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
07/25/2025 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
07/25/2025 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
07/25/2025 SPECIAL INSPECTION FOR INSULATING CONCRETE FILL IS REQUIRED.
07/25/2025 ??? Designs must be submitted and approved prior to ...
07/25/2025 Post-Installed Anchor Inspection Report is required.
07/25/2025 STATE HEALTH LICENSE REQUIRED - PLEASE PROVIDE DOCUMENTATION.
07/25/2025 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
07/25/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
07/25/2025 SPECIAL INSPECTION FOR WELDING IS REQUIRED.
07/25/2025 SPECIAL INSPECTION FOR WOOD FRAMED DIAPHRAGMS AND SHEAR WALLS IS REQUIRED.
09/22/2025 AIR BALANCING REPORT IS REQUIRED.
09/22/2025 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
09/22/2025 COMMISSIONING REPORT IS REQUIRED.
09/22/2025 WATER STERILIZATION REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0725-01348
Permit Status: Inspections
Permit Description: Restricted Record - New Medical Office Building on existing lot - North Building
Date Description Comments
07/15/2025 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
07/15/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0725-01348
Permite Description: Restricted Record - New Medical Office Building on existing lot - North Building
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/28/2025 COT - HCBU - Excavation/Rebar/Zoning N/A Partial Pass Light poles.
10/28/2025 COT - HCEL - Electrical Underground N/A Partial Pass Light poles.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-0725-01348
Permit Description: Restricted Record - New Medical Office Building on existing lot - North Building
Total Completed Inspections - 1
Date Description Inspector Results Comments
10/28/2025 COT - HCEL - Grounding/Bonding Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-2_PLAN SET_V2.PDF DOCUMENTS VIEW
2_ENVELOPE COMCHECK BLDG 1_V1.PDF DOCUMENTS VIEW
2_EQUIPMENT CUT SHEETS_V1.PDF DOCUMENTS VIEW
2_MECHANICAL COMCHECK BLDG 1_V1.PDF DOCUMENTS VIEW
2_SIC BLDG 1-2025-08-21_V1.PDF DOCUMENTS VIEW
2_STRUCTURAL CALCULATIONS_V1.PDF DOCUMENTS VIEW