Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Commercial Building
Address:
1338 S 6TH AV
Address NEW:
1338 S 6TH AV
Apply Date:
07/20/2023
Applicant:
Garett Cunningham
Description:
Watermill Express KIOSK free standing, unmanned water & ice vending stations in two, leased shopping plaza parking spaces. Each kiosk is a fully premanufactured unit that has been inspected, approved, and stamped at the state level, leaving only the foundation and plumbing & electrical connections reviewable and inspected on the local level.

Permit Reviews

Permit Number - TC-COM-0723-01793
Permit Status: Complete
Permit Description: Watermill Express KIOSK free standing, unmanned water & ice vending stations in two, leased shopping plaza parking spaces. Each kiosk is a fully premanufactured unit that has been inspected, approved, and stamped at the state level, leaving only the foundation and plumbing & electrical connections reviewable and inspected on the local level.
Start Date Submittal Complete Date Status  
01/26/2024 COMMERCIAL REVIEW - FULL v.3 02/27/2024 REQUIRES RESUBMIT Review Details
11/03/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/04/2025 REQUIRES RESUBMIT Review Details
07/25/2023 COMMERCIAL REVIEW - FULL v.1 08/29/2023 REQUIRES RESUBMIT Review Details
03/13/2025 COMMERCIAL REVIEW - FULL v.4 04/01/2025 APPROVED Review Details
08/05/2025 COMMERCIAL REVIEW - FULL v.1 08/19/2025 APPROVED Review Details
04/01/2025 RESTAMP - COMMERCIAL v.1 04/03/2025 APPROVED Review Details
11/10/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.2 11/13/2025 APPROVED Review Details
11/24/2023 COMMERCIAL REVIEW - FULL v.2 12/20/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-0723-01793
Permit Status: Complete
Permit Description: Watermill Express KIOSK free standing, unmanned water & ice vending stations in two, leased shopping plaza parking spaces. Each kiosk is a fully premanufactured unit that has been inspected, approved, and stamped at the state level, leaving only the foundation and plumbing & electrical connections reviewable and inspected on the local level.
Date Description Comments
08/29/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
12/19/2023 Post-Installed Anchor Inspection Report is required.
12/19/2023 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
08/29/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
12/14/2023 WATER STERILIZATION REPORT IS REQUIRED.

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-0723-01793
Permit Description: Watermill Express KIOSK free standing, unmanned water & ice vending stations in two, leased shopping plaza parking spaces. Each kiosk is a fully premanufactured unit that has been inspected, approved, and stamped at the state level, leaving only the foundation and plumbing & electrical connections reviewable and inspected on the local level.
Total Completed Inspections - 12
Date Description Inspector Results Comments
05/02/2025 COT - LCBU - Preslab Passed Approved. Okay for concrete placement. 5/2/2025
10/02/2025 COT - HCPL - Rough Soil Passed Sewer tie in. Double clean out at 95' tracer wire in place. Okay to backfill. Shading required. 10/2/2025
10/02/2025 COT - LCEL - Electrical Underground Passed From new transformer location to pad approved. Okay to backfill. Shading required. 10/2/2025
10/02/2025 COT - LCEL - Grounding/Bonding Passed
10/02/2025 BULD - Electrical Clearance Passed Clearance for TEP ECO. 10/2/2025
10/31/2025 COT - LCBU - Building Progress Passed
10/31/2025 ENGR Engineering Final Passed
10/31/2025 COT - HCEL - Outdoor Lighting Passed
10/31/2025 COT - LCPL - Plumbing Final Passed
10/31/2025 COT - LCME - Mechanical Final Passed Heat pump needs to be a minimum of 6" from exterior wall.
10/31/2025 COT - LCEL - Electrical Final Passed
10/31/2025 COT - LCBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-REV1_PLAN SET_V1.PDF DOCUMENTS VIEW
REVISION NARRATIVE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-PLAN SET_V3.PDF DOCUMENTS VIEW
MEP PLANS_V1.PDF DOCUMENTS VIEW
STRUC PLANS_V1.PDF DOCUMENTS VIEW
MEP PLANS_V1.PDF DOCUMENTS VIEW
STRUC PLANS_V1.PDF DOCUMENTS VIEW