Permit: TC-COM-0625-01127
Permit Details
Apply Date:
06/09/2025
Applicant:
Brandy Burke
Description:
Shell only for new restaurant with drive- thru
Permit Reviews
Permit Number - TC-COM-0625-01127
Permit Status: Issued
Permit Description: Shell only for new restaurant with drive- thru
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/16/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/17/2025 | REQUIRES RESUBMIT |
| 08/25/2025 | RESTAMP - COMMERCIAL v.1 | 08/27/2025 | APPROVED |
| 08/15/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/18/2025 | APPROVED |
| 08/20/2025 | COMMERCIAL REVIEW - FULL v.3 | 08/25/2025 | APPROVED |
| 07/15/2025 | COMMERCIAL REVIEW - FULL v.2 | 08/05/2025 | REQUIRES RESUBMIT |
| 06/10/2025 | COMMERCIAL REVIEW - FULL v.1 | 07/01/2025 | REQUIRES RESUBMIT |
| 08/13/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/14/2025 | APPROVED |
| 09/23/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 09/24/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0625-01127
Permit Status: Issued
Permit Description: Shell only for new restaurant with drive- thru
Total Outstanding Activity Conditions - 9
| Date | Name |
|---|---|
| 06/10/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
| 06/27/2025 | SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED. |
| 08/25/2025 | SPECIAL INSPECTION OF CONCRETE CONSTRUCTION IS REQUIRED.(SECTION 1705.3 AND TABLE 1705.3 CONCRETE MATERIAL SAMPLING AND TESTING, REBAR OBSERVATIONS. TAKE SET OF (3) CYLINDERS FOR EVERY 50 C.Y. BUT NOT LESS THAN ONE SET OF SAMPLES PER DAY'S WORK AND PER MIX.) |
| 08/25/2025 | SPECIAL INSPECTION OF MASONRY CONSTRUCTION IS REQUIRED. (SECTION 1705.4 AND TMS 402 TABLE 3 AND 4, LEVEL 2) |
| 08/25/2025 | SPECIAL INSPECTION OF POST-INSTALLED ANCHORS IS REQUIRED.(TABLE 1705.3) |
| 08/25/2025 | SPECIAL INSPECTION OF SEISMIC ANCHORAGE AND BRACING FOR NONSTRUCTURAL COMPONENTS IS REQUIRED.(SECTION 1705.13 AND 1705.14 |
| 08/25/2025 | SPECIAL INSPECTION OF SEISMIC INSPECTIONS FOR WOOD IS REQUIRED.(SECTION 1705.13. PERIODIC SPECIAL INSPECTION FOR NAILING, BOLTING, ANCHORING, AND FASTENING OF ELEMENTS PART OF SHEAR WALLS, SHEAR PANELS, DRAG STRUTS AND HOLDOWNS. AT SHEAR WALL SW-C AND ASSOCIATED DRAG STRUT ONLY. |
| 08/25/2025 | SPECIAL INSPECTION OF SOILS IS REQUIRED. (SECTION 1705.6 FOUNDATION BEARING, EXCAVATION, FILL PLACEMENT.) |
| 08/25/2025 | SPECIAL INSPECTION OF STEEL CONSTRUCTION IS REQUIRED.(SECTION 1705.2, AND AISC 360. PERIODIC OBSERVATIONS OF CONNECTION, WELDERS & FIELD WELDING). |
Conditions
Permit Number - TC-COM-0625-01127
Permit Status: Issued
Permit Description: Shell only for new restaurant with drive- thru
| Date | Description | Comments |
|---|---|---|
| 06/10/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 06/10/2025 | Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection. | |
| 06/30/2025 | Separate submittal to PC Industrial Wastewater Control is required for new interceptors and separators. Contact Kelsey.McMonagle@pima.gov or Adam.DeLaTorre@pima.gov for review and assessment of the proposed grease interceptor. | |
| 06/10/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 06/27/2025 | A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0625-01127
Permite Description: Shell only for new restaurant with drive- thru
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/04/2025 | COT - LCEL - Grounding/Bonding | N/A | Partial Pass | Ufer connection to the bottom reinforcement. |
| 10/21/2025 | COT - LCEL - Electrical Underground | N/A | Partial Pass | |
| 11/25/2025 | COT - LCEL - Electrical Intermediate | N/A | Partial Pass | Underground inside |
| 12/10/2025 | COT - LCBU - Preslab | N/A | Not Applicable |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0625-01127
Permit Description: Shell only for new restaurant with drive- thru
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/08/2025 | COT - LCBU - Stem Wall/Retaining Wall | Passed | Reinforcements per plan. Okay for concrete placement. 9/8/2025 | |
| 09/22/2025 | COT - LCPL - Sewer | Passed | ||
| 10/06/2025 | COT - LCBU - Framing | Passed | ||
| 10/07/2025 | COT - LCPL - Plumbing Roof Drains | Passed | ||
| 10/07/2025 | COT - LCBU - Roof Nailing | Passed | ||
| 10/22/2025 | COT - LCEL - Electrical Underground | Passed | ||
| 12/01/2025 | COT - LCPL - Rough Soil | Passed | All underground inspected by Robert Chandler, Super wanted drywall inspection. Ok to tape and mud | |
| 12/10/2025 | COT - LCPL - Yard Water Line | Passed | ||
| 12/10/2025 | COT - LCBU - Excavation/Rebar/Zoning | Passed | ||
| 12/10/2025 | COT - LCBU - Masonry Pregrout | Passed | ||
| 12/10/2025 | COT - LCPL - Plumbing Intermediate | Passed | ||
| 12/12/2025 | BULD - Electrical Clearance | Passed | Passed 12/12/25 CLEARANCE ECO |