Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Commercial Building
Address:
7101 E 22ND ST
Address NEW:
7101 E 22ND ST
Apply Date:
06/09/2025
Applicant:
Brandy Burke
Description:
Shell only for new restaurant with drive- thru

Permit Reviews

Permit Number - TC-COM-0625-01127
Permit Status: Issued
Permit Description: Shell only for new restaurant with drive- thru
Start Date Submittal Complete Date Status  
09/16/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/17/2025 REQUIRES RESUBMIT Review Details
08/25/2025 RESTAMP - COMMERCIAL v.1 08/27/2025 APPROVED Review Details
08/15/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/18/2025 APPROVED Review Details
08/20/2025 COMMERCIAL REVIEW - FULL v.3 08/25/2025 APPROVED Review Details
07/15/2025 COMMERCIAL REVIEW - FULL v.2 08/05/2025 REQUIRES RESUBMIT Review Details
06/10/2025 COMMERCIAL REVIEW - FULL v.1 07/01/2025 REQUIRES RESUBMIT Review Details
08/13/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/14/2025 APPROVED Review Details
09/23/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.2 09/24/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0625-01127
Permit Status: Issued
Permit Description: Shell only for new restaurant with drive- thru
Total Outstanding Activity Conditions - 9
Date Name
06/10/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
06/27/2025 SPECIAL INSPECTION FOR SPECIAL MOMENT RESISTING STEEL FRAMES IS REQUIRED.
08/25/2025 SPECIAL INSPECTION OF CONCRETE CONSTRUCTION IS REQUIRED.(SECTION 1705.3 AND TABLE 1705.3 CONCRETE MATERIAL SAMPLING AND TESTING, REBAR OBSERVATIONS. TAKE SET OF (3) CYLINDERS FOR EVERY 50 C.Y. BUT NOT LESS THAN ONE SET OF SAMPLES PER DAY'S WORK AND PER MIX.)
08/25/2025 SPECIAL INSPECTION OF MASONRY CONSTRUCTION IS REQUIRED. (SECTION 1705.4 AND TMS 402 TABLE 3 AND 4, LEVEL 2)
08/25/2025 SPECIAL INSPECTION OF POST-INSTALLED ANCHORS IS REQUIRED.(TABLE 1705.3)
08/25/2025 SPECIAL INSPECTION OF SEISMIC ANCHORAGE AND BRACING FOR NONSTRUCTURAL COMPONENTS IS REQUIRED.(SECTION 1705.13 AND 1705.14
08/25/2025 SPECIAL INSPECTION OF SEISMIC INSPECTIONS FOR WOOD IS REQUIRED.(SECTION 1705.13. PERIODIC SPECIAL INSPECTION FOR NAILING, BOLTING, ANCHORING, AND FASTENING OF ELEMENTS PART OF SHEAR WALLS, SHEAR PANELS, DRAG STRUTS AND HOLDOWNS. AT SHEAR WALL SW-C AND ASSOCIATED DRAG STRUT ONLY.
08/25/2025 SPECIAL INSPECTION OF SOILS IS REQUIRED. (SECTION 1705.6 FOUNDATION BEARING, EXCAVATION, FILL PLACEMENT.)
08/25/2025 SPECIAL INSPECTION OF STEEL CONSTRUCTION IS REQUIRED.(SECTION 1705.2, AND AISC 360. PERIODIC OBSERVATIONS OF CONNECTION, WELDERS & FIELD WELDING).

Conditions

Permit Number - TC-COM-0625-01127
Permit Status: Issued
Permit Description: Shell only for new restaurant with drive- thru
Date Description Comments
06/10/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
06/10/2025 Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection.
06/30/2025 Separate submittal to PC Industrial Wastewater Control is required for new interceptors and separators. Contact Kelsey.McMonagle@pima.gov or Adam.DeLaTorre@pima.gov for review and assessment of the proposed grease interceptor.
06/10/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
06/27/2025 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-0625-01127
Permite Description: Shell only for new restaurant with drive- thru
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
09/04/2025 COT - LCEL - Grounding/Bonding N/A Partial Pass Ufer connection to the bottom reinforcement.
10/21/2025 COT - LCEL - Electrical Underground N/A Partial Pass
11/25/2025 COT - LCEL - Electrical Intermediate N/A Partial Pass Underground inside
12/10/2025 COT - LCBU - Preslab N/A Not Applicable

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-0625-01127
Permit Description: Shell only for new restaurant with drive- thru
Total Completed Inspections - 12
Date Description Inspector Results Comments
09/08/2025 COT - LCBU - Stem Wall/Retaining Wall Passed Reinforcements per plan. Okay for concrete placement. 9/8/2025
09/22/2025 COT - LCPL - Sewer Passed
10/06/2025 COT - LCBU - Framing Passed
10/07/2025 COT - LCPL - Plumbing Roof Drains Passed
10/07/2025 COT - LCBU - Roof Nailing Passed
10/22/2025 COT - LCEL - Electrical Underground Passed
12/01/2025 COT - LCPL - Rough Soil Passed All underground inspected by Robert Chandler, Super wanted drywall inspection. Ok to tape and mud
12/10/2025 COT - LCPL - Yard Water Line Passed
12/10/2025 COT - LCBU - Excavation/Rebar/Zoning Passed
12/10/2025 COT - LCBU - Masonry Pregrout Passed
12/10/2025 COT - LCPL - Plumbing Intermediate Passed
12/12/2025 BULD - Electrical Clearance Passed Passed 12/12/25 CLEARANCE ECO

Documents

File Name Document Type  
USE THIS ONE SUB4 TRUSS LAYOUT - CALCS 8.20.25 - STRUCT REVIEWED_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
SIC-CHIPOTLE 22ND - KOLB-2025-08-12_V1.PDF DOCUMENTS VIEW