Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0624-01276
Permit Details
Apply Date:
06/30/2024
Applicant:
Lisa Bowers
Description:
Tentative Plat - SFR at The Bridges B-1. Lots 1 thru 126, and Common Areas "A" (private streets, uti
Permit Reviews
Permit Number - TC-COM-0624-01276
Permit Status: Inspections
Permit Description: Tentative Plat - SFR at The Bridges B-1. Lots 1 thru 126, and Common Areas "A" (private streets, uti
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/02/2024 | COMMERCIAL FENCE/WALL v.1 | 07/22/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0624-01276
Permit Status: Inspections
Permit Description: Tentative Plat - SFR at The Bridges B-1. Lots 1 thru 126, and Common Areas "A" (private streets, uti
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
07/22/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
07/22/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
07/22/2024 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0624-01276
Permite Description: Tentative Plat - SFR at The Bridges B-1. Lots 1 thru 126, and Common Areas "A" (private streets, uti
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/05/2024 | COT - LCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | Partial pass from lot 26 - 40. Reinforcement per plan. Okay for concrete placement in footings. 11/5/2024 |
11/19/2024 | COT - LCBU - Masonry Pregrout | N/A | Partial Pass | Retaining wall at Southeast property, approximately 700’ (lots 42 - 27?). Ok to place grout in progress areas. |