Permit Details

Status:
Needs Resubmittal
Type:
Commercial Building
Apply Date:
06/14/2024
Applicant:
Alexis Neuroth
Description:
Ground Up Retail Building

Permit Reviews

Permit Number - TC-COM-0624-01147
Permit Status: Needs resubmittal
Permit Description: Ground Up Retail Building
Start Date Submittal Complete Date Status  
06/17/2024 COMMERCIAL REVIEW - FULL v.1 07/26/2024 REQUIRES RESUBMIT Review Details
05/06/2025 RESTAMP - COMMERCIAL v.1 05/12/2025 APPROVED Review Details
10/08/2025 COMMERCIAL REVIEW - FULL REVISION v.1 11/06/2025 REQUIRES RESUBMIT Review Details
11/27/2024 RESTAMP - COMMERCIAL v.1 12/03/2024 APPROVED Review Details
11/14/2025 COMMERCIAL REVIEW - FULL REVISION v.2 12/10/2025 REQUIRES RESUBMIT Review Details
12/10/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/10/2024 APPROVED Review Details
02/24/2025 COMMERCIAL REVIEW - FULL v.1 04/01/2025 REQUIRES RESUBMIT Review Details
04/23/2025 COMMERCIAL REVIEW - FULL v.2 04/28/2025 REQUIRES RESUBMIT Review Details
10/24/2024 COMMERCIAL REVIEW - FULL v.3 11/27/2024 APPROVED Review Details
08/19/2025 COMMERCIAL REVIEW - FULL REVISION v.1 09/11/2025 APPROVED Review Details
05/01/2025 COMMERCIAL REVIEW - FULL v.3 05/06/2025 APPROVED Review Details
09/12/2024 COMMERCIAL REVIEW - FULL v.2 10/14/2024 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0624-01147
Permit Status: Needs resubmittal
Permit Description: Ground Up Retail Building
Total Outstanding Activity Conditions - 8
Date Name
10/30/2024 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
10/30/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/30/2024 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
10/30/2024 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
10/30/2024 SPECIAL INSPECTION FOR FOUNDATION/EXCAVATION IS REQUIRED.
10/30/2024 SPECIAL INSPECTION FOR WELDING IS REQUIRED.
11/14/2025 Please submit a separate sign permit for an signs associated with this projet.
12/05/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Conditions

Permit Number - TC-COM-0624-01147
Permit Status: Needs resubmittal
Permit Description: Ground Up Retail Building
Date Description Comments
06/17/2024 Please contact Pima County Addressing to verify the official address. Addressing@pima.gov or 520-724-9512
06/17/2024 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
10/29/2024 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Needs Resubmittal
Permit Number: TC-COM-0624-01147
Permite Description: Ground Up Retail Building
Total Outstanding Inspections - 15
Last Inspection Date Description Inspector Results Comments
05/12/2025 COT - HCEL - Grounding/Bonding N/A Partial Pass 5/12/25: partial for UFER
08/06/2025 COT - FCON - Sprinkler - Final N/A Partial Pass Riser stub out and thrust block were looked at
05/29/2025 COT - HCPL - Rough Soil N/A Partial Pass 5/29/2025 Restrooms 104 and 105 janitors closet 108 restroom hall 103 on the water plan detail 3 on page P1.2. Approved okay to backfill progress areas. Shading is required.
8” roof drain on Grid line E column 9. 8” roof drain on Grid line B column 9. Okay to proceed progress areas. Shading is required for backfill.
Partial pass. Main water line 3” riser in place at Grid line A column 5.
10/10/2025 COT - HCEL - Electrical Underground N/A Not Ready
10/23/2025 COT - HCPL - Plumbing Intermediate N/A Canceled 10-23-25: canceled by contractor.
10/23/2025 COT - HCME - Mechanical Intermediate N/A Partial Pass 10-23-25: verified pookie joints for ducts at Gridline D-F/2-7. Okay to continue with construction at progress areas.
11/06/2025 COT - HCEL - Electrical Intermediate N/A Partial Pass 11/6/25: Electrical in wall approved at exterior walls at Area B (GL A/1 - D/1), Area A (GL E.5/1 - H/1-3), Area D (GL G/6 - F/8)
10/08/2025 COT - HCBU - Preslab N/A Partial Pass Slab area Northeast corner of building , North of archery range. Ok to,place concrete in slab area.
11/24/2025 BULD - Electrical Clearance N/A Partial Pass Clearance for TEP ECO. HOUSE PANEL. 11/24/2025
12/02/2025 COT - HCEL - Outdoor Lighting N/A Partial Pass Partial pass. Total of 7 light pole bases on the west end of building. Okay for concrete placement. Refer to highlighted notes on the site lighting page. 12/2/2025
10/08/2025 COT - HCME - Mechanical Progress N/A Partial Pass West offices and restrooms; archery range: ducts wrapped except for joints. Ok to continue wrapping existing duct systems.
12/31/2025 COT - HCPL - Plumbing Progress N/A Partial Pass
05/16/2025 COT - HCBU - Excavation/Rebar/Zoning N/A Partial Pass 4-29-25, excavation/reinforcement for 14 column spread footers on south end verified per plan. Detail F-6 calls for 7-#5 rebar top/bottom and F-8-calls for 9-#6 rebar top/bottom. Okay to pour footers at progress areas.
4-30-25, excavation/reinforcement on a total of 18 interior spread footings verified per approved plans.See Detail's F-6 & F4.5, F3X6. Okay to pour concrete.
5-2-25, excavation/reinforcement on a total of 33 spread footings verified per approved plans-see detail F-4, F-6, F-8. Okay to pour concrete.
5/12/25: reinforcement per plans at exterior continuous perimeter footer at GL (A/0-10, A-D/11). Ok to proceed with progress areas.
5/16/25: reinforcement per approved plans at continuous perimeter panel footings from GL A-G.5/2-2
12/16/2025 COT - HCEL - Electrical Progress N/A Partial Pass 12-16-25: in wall electrical at gang restrooms, Area A, LSS room, cash count room, ap office approved-okay to continue with construction at progress areas
10/23/2025 COT - HCBU - Framing N/A Partial Pass 10-23-25: interior metal framing at Gridline A-B/1-9 approved. Okay to continue with construction at progress areas. electrical room 109 & framing at tower between Gridline A/5-6 approved.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BPS TUCSON AZ_CCD004_REV NAR_20250814_V1.PDF DOCUMENTS VIEW
BPS TUCSON AZ_CCD004_REV SHEETS COMBINED_20250818_V1.PDF DOCUMENTS VIEW
BASSPRO TUCSONAZ FULLPLANS_CCD003_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BPS TUCSON AZ_CCD003 COMCHECK_V1.PDF DOCUMENTS VIEW
BPS TUCSON AZ_CCD003 REV NAR COMCHECK_V1.PDF DOCUMENTS VIEW
MECHANICAL COMPLIANCE CERTIFICATE COMCHECK_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
SPECIAL INSPECTIONS INTERMEDIATE CERTIFICATE TC-COM-0624-01147 BASS PRO-2024-12-04_V1.PDF DOCUMENTS VIEW
CONS-BASSPRO TUCSONAZ FULLPLANS CCD2_V3.PDF DOCUMENTS VIEW
BASSPRO TUCSONAZ PLUMB NARRATIVE CCD2_V1.PDF DOCUMENTS VIEW
BASSPRO TUCSONAZ FIREPLACE CUTSHEET_V2.PDF DOCUMENTS VIEW
BASSPRO TUSCON AZ ELECCOMCHECK2_V2.PDF DOCUMENTS VIEW
BASSPRO TUSCON AZ HVACLOADCALCS_V2.PDF DOCUMENTS VIEW
BASSPRO TUSCON AZ RESPONSELETTERCCD2_V2.PDF DOCUMENTS VIEW