Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Commercial Building
Address NEW:
325 W 2ND ST BLDG 2
Apply Date:
05/27/2025
Applicant:
Charles Pifer
Description:
TENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE

Permit Reviews

Permit Number - TC-COM-0525-01056
Permit Status: Issued
Permit Description: TENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE
Start Date Submittal Complete Date Status  
05/30/2025 COMMERCIAL REVIEW - LIMITED v.1 06/17/2025 APPROVED Review Details
09/04/2025 COMMERCIAL REVIEW - FULL REVISION v.1 09/30/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0525-01056
Permit Status: Issued
Permit Description: TENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE
Total Outstanding Activity Conditions - 2
Date Name
09/25/2025 AIR BALANCING REPORT IS REQUIRED.
09/25/2025 WATER STERILIZATION REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0525-01056
Permit Status: Issued
Permit Description: TENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE
Date Description Comments
05/30/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-COM-0525-01056
Permite Description: TENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
08/19/2025 COT - BULD - SWG Clearance N/A Not Applicable No gas service to building.
10/09/2025 COT - LCEL - Electrical Final N/A Not Ready
COT - FCON - Alarm - Final N/A Not Ready sprinkler company needs to call in their permit.
COT - FCON - Fire - Final N/A Not Ready sprinkler company needs to call in their permit.
COT - FCON - Sprinkler - Final N/A Not Ready sprinkler company needs to call in their permit.

Completed Inspections

Permit Status: Issued
Permit Number: TC-COM-0525-01056
Permit Description: TENANT IMPROVEMENT TO RENOVATE (2) CURRENTLY DISUSED ROOMS IN EXISTING, OCCUPIED DUNBAR SCHOOL BUILDING. WORK INCLUDES NEW MECHANICAL, ELECTRICAL AND LIGHTING AS WELL AS PATCHING, PAINTING AND FLOOR COVERINGS. ALL EXITS AND DOORS ARE EXISTING, THERE IS NO CHANGE TO EGRESS. NO PLUMBING WORK. ALL RESTROOMS ARE EXISTING. REWORK EXISTING FIRE SPRINKLER SYSTEM TO CONNECT TO NEW CEILING NO EXTERIOR WORK. NO STRUCTURAL WORK. REV1_A bathroom has been added to tenant space A119. This includes plumbing for a new toilet and sink, a new tankless water heater, exhaust fan, lights and bathroom accessories. Sheets below have been updated and new ones included to represent the added scope of work. Revised or Added (*) Sheets: G-100 – DUNBAR BUILDING TITLE SHEET A-A110 – FLOOR PLAN – LEVEL 1 TI A-A111 – ENLARGED PLANS AND INTERIOR ELEVATIONS A-A111.1 – TENANT SPACE BATHROOM INTERIOR ELEVATIONS A-A112 – LEVEL 1 RCP - TI A-A501 – WALL TYPES AND MILLWORK MD101 – MECHANICAL DEMOLITION FLOOR PLAN M101 – MECHANICAL FLOOR PLAN M201 – MECHANICAL ROOF PLAN M301 – MECHANICAL EQUIPMENT SCHEDULES, CALCULATIONS P001 – PLUMBING GENERAL INFORMATION P101 – PLUMBING FLOOR PLAN P201 – PLUMBING ISOMETRICS E101 – ELECTRICAL FLOOR PLANS E301 – ELECTRICAL ONE-LINE AND SCHEDULE
Total Completed Inspections - 10
Date Description Inspector Results Comments
08/12/2025 COT - LCBU - Framing Passed
08/12/2025 BULD - Electrical Clearance Passed No electric clearance required, service,is active.
08/19/2025 COT - LCEL - Electrical Intermediate Passed Office room #111 and archives room #116.
08/19/2025 COT - LCEL - Electrical Above Ceiling Passed Office room #111 and archives room #116.
09/24/2025 TRSP - ROW - Final/Close-Out Passed
10/10/2025 COT - LCEL - Electrical Final Passed
10/27/2025 COT - LCBU - Building Final Passed
10/27/2025 COT - LCME - Mechanical Final Passed
10/27/2025 COT - LCPL - Plumbing Final Passed
10/27/2025 COT - LCME - Mechanical Intermediate Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-DUNBAR TI - REVISION 1 SET 9.4.25_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-DUNBAR BUILDING TI CDS 5.27.25_V1.PDF DOCUMENTS VIEW