Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-COM-0424-00735
Permit Details
Status:
Inspections Complete
Type:
Commercial Building
Address:
7500 E VOYAGER RD UNIT 77
Address NEW:
7500 E VOYAGER RD UNIT 77
Apply Date:
04/24/2024
Applicant:
Ken Larison
Description:
New Pool & Spa for the Voyager RV Park
Permit Reviews
Permit Number - TC-COM-0424-00735
Permit Status: Inspections complete
Permit Description: New Pool & Spa for the Voyager RV Park
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/27/2024 | RESTAMP - COMMERCIAL v.1 | 06/28/2024 | APPROVED |
| 06/13/2024 | COMMERCIAL POOLS v.4 | 06/27/2024 | APPROVED |
| 07/31/2024 | COMMERCIAL POOLS v.1 | 08/15/2024 | APPROVED |
| 05/20/2024 | COMMERCIAL POOLS v.3 | 06/03/2024 | REQUIRES RESUBMIT |
| 04/24/2024 | COMMERCIAL POOLS v.1 | 05/13/2024 | REQUIRES RESUBMIT |
| 05/20/2024 | COMMERCIAL POOLS v.2 | 05/20/2024 | REQUIRES RESUBMIT |
| 12/20/2024 | COMMERCIAL POOLS REVISION v.1 | 01/09/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0424-00735
Permit Status: Inspections complete
Permit Description: New Pool & Spa for the Voyager RV Park
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 06/27/2024 | COUNTY HEALTH INSPECTION IS REQUIRED - PLEASE PROVIDE DOCUMENTATION THAT THE INSPECTION HAS BEEN COMPLETED AND PASSED. |
| 06/27/2024 | Electrical panel schedule must be resubmitted, reviewed, and approved prior to any inspections being called in. |
Conditions
Permit Number - TC-COM-0424-00735
Permit Status: Inspections complete
Permit Description: New Pool & Spa for the Voyager RV Park
| Date | Description | Comments |
|---|---|---|
| 06/27/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 07/02/2024 | Prior to Issuance: This project requires issuance of a Development Package (DP) permit prior to issuance of this permit. Prior to TCO/Final: This project requires full completion of a Development Package (DP) permit prior to Temporary C of O and/or final completion this permit. | |
| 06/27/2024 | ADEQ - Approval to Construct MUST BE UPLOADED PRIOR TO ISSUANCE. | |
| 06/27/2024 | County Health Permit - Approval by Pima County Health Dept for a semi public pool |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-COM-0424-00735
Permite Description: New Pool & Spa for the Voyager RV Park
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/07/2025 | BULD - Electrical Clearance | N/A | Not Applicable | |
| 08/27/2024 | Pool/Spa - Electric | N/A | Partial Pass | okay to backfill progress areas. shading is required. 8/27/2024 |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-COM-0424-00735
Permit Description: New Pool & Spa for the Voyager RV Park
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2024 | Pool/Spa - Plumbing | Passed | okay to backfill. shading is required. 8/27/2024 | |
| 08/28/2024 | Pool/Spa - Pre-Gunite | Passed | ||
| 08/28/2024 | Pool/Spa - Bonding Grip | Passed | ||
| 01/17/2025 | COT - BULD - SWG Clearance | Passed | Passed SWG CLEARANCE 1/17/25 | |
| 01/17/2025 | COT - LCPL - Gas Final | Passed | Passed SWG CLEARANCE 1/17/25 ok to connect tank and backfill | |
| 01/17/2025 | Pool/Spa - Gas | Passed | Passed SWG CLEARANCE 1/17/25 ok to connect tank and backfill | |
| 04/07/2025 | SITE - Zoning Final | Passed | No issues on zoning and pool barrier is solid. | |
| 04/07/2025 | TRSP - ROW - Final/Close-Out | Passed |