Permit: TC-COM-0326-00389
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
8940 E RITA PARK DR
Address NEW:
8940 E RITA PARK DR
Apply Date:
03/19/2026
Applicant:
Brandon Slater
Description:
Project Scope is a like for like replacement of the existing building Roof Top Units with New Roof Top Units. Roof curb adapters will be included with the new roof top units so that the team can utilize the existing roof openings. Work will be conducted in two phases due to Roof Top Units being delivered at various times.
Permit Reviews
Permit Number - TC-COM-0326-00389
Permit Status: Inspections
Permit Description: Project Scope is a like for like replacement of the existing building Roof Top Units with New Roof Top Units. Roof curb adapters will be included with the new roof top units so that the team can utilize the existing roof openings. Work will be conducted in two phases due to Roof Top Units being delivered at various times.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/27/2026 | ADMINISTRATIVE v.2 | 05/27/2026 | APPROVED |
| 10/27/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/29/2026 | APPROVED |
| 03/24/2026 | COMMERCIAL REVIEW - FULL v.1 | 04/06/2026 | APPROVED |
| 04/06/2026 | ADMINISTRATIVE v.1 | 04/06/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-0326-00389
Permit Status: Inspections
Permit Description: Project Scope is a like for like replacement of the existing building Roof Top Units with New Roof Top Units. Roof curb adapters will be included with the new roof top units so that the team can utilize the existing roof openings. Work will be conducted in two phases due to Roof Top Units being delivered at various times.
| Date | Description | Comments |
|---|---|---|
| 03/24/2026 | AIR BALANCING REPORT IS REQUIRED. Verify the total supply airflow and the outside airflow are at least equal to that which the previous AC units provided. | |
| 03/24/2026 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 03/24/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0326-00389
Permite Description: Project Scope is a like for like replacement of the existing building Roof Top Units with New Roof Top Units. Roof curb adapters will be included with the new roof top units so that the team can utilize the existing roof openings. Work will be conducted in two phases due to Roof Top Units being delivered at various times.
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2026 | COT - LCEL - Electrical Underground | N/A | Not Applicable | |
| 09/30/2026 | COT - LCEL - Electrical Above Ceiling | N/A | Not Applicable | |
| 09/30/2026 | COT - FCON - Fire - Final | N/A | Not Applicable | |
| COT - LCBU - Building Final | N/A | Scheduled | ||
| COT - LCME - Mechanical Final | N/A | Scheduled |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0326-00389
Permit Description: Project Scope is a like for like replacement of the existing building Roof Top Units with New Roof Top Units. Roof curb adapters will be included with the new roof top units so that the team can utilize the existing roof openings. Work will be conducted in two phases due to Roof Top Units being delivered at various times.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2026 | COT - LCEL - Electrical Final | Passed | ||
| 09/30/2026 | COT - LCME - Mechanical Intermediate | Passed | ||
| 09/30/2026 | COT - LCEL - Electrical Intermediate | Passed |
Scheduled Inspections
Scheduled Inspections - TC-COM-0326-00389
Status: Inspections
Description: Project Scope is a like for like replacement of the existing building Roof Top Units with New Roof Top Units. Roof curb adapters will be included with the new roof top units so that the team can utilize the existing roof openings. Work will be conducted in two phases due to Roof Top Units being delivered at various times.
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 11/06/2026 | COT - LCBU - Building Final | Scheduled | |
| 11/06/2026 | COT - LCME - Mechanical Final | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.