Permit: TC-COM-0325-00625
Permit Details
Status:
Issued
Type:
Commercial Building
Address:
7275 S TUCSON BL UNIT 165
Address NEW:
7275 S TUCSON BL UNIT 165
Apply Date:
03/27/2025
Applicant:
Anthony Demattei
Description:
Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
Permit Reviews
Permit Number - TC-COM-0325-00625
Permit Status: Issued
Permit Description: Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/13/2025 | RESTAMP - COMMERCIAL v.1 | 11/18/2025 | APPROVED |
| 11/18/2025 | ADMINISTRATIVE v.1 | 11/18/2025 | REQUIRES RESUBMIT |
| 10/29/2025 | COMMERCIAL REVIEW - LIMITED v.4 | 11/13/2025 | APPROVED |
| 03/20/2026 | COMMERCIAL REVIEW - FULL REVISION v.1 | 04/14/2026 | APPROVED |
| 11/25/2025 | ADMINISTRATIVE v.2 | 11/25/2025 | REQUIRES RESUBMIT |
| 10/08/2025 | COMMERCIAL REVIEW - LIMITED v.2 | 10/08/2025 | REQUIRES RESUBMIT |
| 10/09/2025 | COMMERCIAL REVIEW - LIMITED v.3 | 10/24/2025 | REQUIRES RESUBMIT |
| 04/02/2025 | COMMERCIAL REVIEW - LIMITED v.1 | 04/18/2025 | REQUIRES RESUBMIT |
| 12/19/2025 | ADMINISTRATIVE v.3 | 12/19/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0325-00625
Permit Status: Issued
Permit Description: Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/24/2025 | Submit the State installation permit and State C of O to Final Inspections by the City of Tucson |
Conditions
Permit Number - TC-COM-0325-00625
Permit Status: Issued
Permit Description: Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
| Date | Description | Comments |
|---|---|---|
| 04/02/2025 | Please confirm address for permit application. Some documents reference different addresses. See Sheet CV-1 which references 7274 S Tucson Blvd. Please review all documents to ensure the address is equivalent. | |
| 04/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 04/10/2026 | Please submit a separate sign permit for an signs associated with this projet. | |
| 04/02/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/18/2025 | 1. Obtain State Approval/Sealed Plans & submit prior to Issuance of building permit. 2. NOTE to Applicant: Coordinate with the State for their Inspection of the FBB during installation. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-0325-00625
Permite Description: Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2026 | COT - FCON - Sprinkler - Final | N/A | Not Applicable | |
| 01/22/2026 | COT - LCBU - Preslab | N/A | Not Applicable | 1-22-26: not applicable. |
| 01/22/2026 | PDSD Building Division - Unspecified In-Field | N/A | Partial Pass | 1-22-26: pending RFI for electrical work on a key dispenser. |
| 01/22/2026 | BULD - Electrical Clearance | N/A | Not Applicable | 1-22-26: not applicable. |
| 06/29/2026 | COT - LCEL - Electrical Final | N/A | Re-inspection required | 6-29-26: bollard height are not per approved plans. Plans show bollards at 5'but installed bollards are 4'. Either install bollards to match plans or submit an RFI to the city for review. Also, have electrician on site so that I may verify cable connections at share box and access to electrical room is required. |
| 06/29/2026 | COT - LCBU - Building Final | N/A | Re-inspection required | 6-29-26: bollard height are not per approved plans. Plans show bollards at 5'but installed bollards are 4'. Either install bollards to match plans or submit an RFI to the city for review. Also, have electrician on site so that I may verify cable connections at share box and access to electrical room is required. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-0325-00625
Permit Description: Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2026 | COT - FCON - Fire - Final | Passed | ||
| 01/22/2026 | ENGR Engineering Final | Passed | ||
| 06/29/2026 | COT - LCEL - Electrical Intermediate | Passed | 6-29-26: electrical intermediates approved. |
Scheduled Inspections
Scheduled Inspections - TC-COM-0325-00625
Status: Issued
Description: Replace existing customer service booth with new prefabricated customer service booth. REV #1 - adding Sharebox key box kiosk & bollards
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 07/01/2026 | COT - LCBU - Building Final | Scheduled | |
| 07/01/2026 | COT - LCEL - Electrical Final | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.