Permit: TC-COM-0324-00523
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
2950 N ALVERNON WY UNIT 2102
Address NEW:
2950 N ALVERNON WY UNIT 2102
Apply Date:
03/26/2024
Applicant:
John Hains
Description:
FIRE RESTORATION TO AN EXISTING APARTMENT THAT WAS DAMAGED AND WILL BE REBUILD LIKE FOR LIKE. NO ADDITIONAL SQUARE FOOTAGE ADDED. ALL EXISTING SITE CONDITIONS TO REMAIN AS IS.
Permit Reviews
Permit Number - TC-COM-0324-00523
Permit Status: Inspections
Permit Description: FIRE RESTORATION TO AN EXISTING APARTMENT THAT WAS DAMAGED AND WILL BE REBUILD LIKE FOR LIKE. NO ADDITIONAL SQUARE FOOTAGE ADDED. ALL EXISTING SITE CONDITIONS TO REMAIN AS IS.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/27/2024 | COMMERCIAL REVIEW - FULL v.1 | 04/30/2024 | REQUIRES RESUBMIT |
| 05/13/2024 | COMMERCIAL REVIEW - FULL v.2 | 05/13/2024 | APPROVED |
Conditions
Permit Number - TC-COM-0324-00523
Permit Status: Inspections
Permit Description: FIRE RESTORATION TO AN EXISTING APARTMENT THAT WAS DAMAGED AND WILL BE REBUILD LIKE FOR LIKE. NO ADDITIONAL SQUARE FOOTAGE ADDED. ALL EXISTING SITE CONDITIONS TO REMAIN AS IS.
| Date | Description | Comments |
|---|---|---|
| 05/13/2024 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 04/30/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0324-00523
Permite Description: FIRE RESTORATION TO AN EXISTING APARTMENT THAT WAS DAMAGED AND WILL BE REBUILD LIKE FOR LIKE. NO ADDITIONAL SQUARE FOOTAGE ADDED. ALL EXISTING SITE CONDITIONS TO REMAIN AS IS.
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2024 | COT - LCEL - Electrical Intermediate | N/A | Re-inspection required | 1-Circuitry does not match approved plans. 2-Install nail plate at bottom of floor joist in kitchen for Waite protection. 3-Obtain revision detailing how firewall will be maintained, including drop ceilings and behind walls, nailers, etc. |
| 10/04/2024 | COT - HCPL - Plumbing Intermediate | N/A | Re-inspection required | 1-Circuitry does not match approved plans. 2-Install nail plate at bottom of floor joist in kitchen for Waite protection. 3-Obtain revision detailing how firewall will be maintained, including drop ceilings and behind walls, nailers, etc. |
| 07/02/2025 | COT - LCBU - Building Final | N/A | Re-inspection required | 7-2-25: per plans-missing fire sprinklers. Have architect submit a revision to the city for review and approval. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0324-00523
Permit Description: FIRE RESTORATION TO AN EXISTING APARTMENT THAT WAS DAMAGED AND WILL BE REBUILD LIKE FOR LIKE. NO ADDITIONAL SQUARE FOOTAGE ADDED. ALL EXISTING SITE CONDITIONS TO REMAIN AS IS.
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2024 | COT - LCME - Mechanical Intermediate | Passed | ||
| 11/07/2024 | COT - LCEL - Electrical Intermediate | Passed | ||
| 11/07/2024 | COT - HCPL - Plumbing Intermediate | Passed | ||
| 11/07/2024 | BULD - Electrical Clearance | Passed | ||
| 07/02/2025 | COT - LCEL - Electrical Above Ceiling | Passed | 7-2-25: approved | |
| 07/02/2025 | COT - LCEL - Electrical Final | Passed | 7-2-25: electrical final approved. | |
| 07/02/2025 | COT - LCME - Mechanical Final | Passed | 7-2-25: mechanical final approved. | |
| 07/02/2025 | COT - LCPL - Plumbing Final | Passed | 7-2-25: plumbing final approved. |