Permit: TC-COM-0324-00518
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
765 W LIMBERLOST DR
Address NEW:
765 W LIMBERLOST DR
Apply Date:
03/25/2024
Applicant:
Joe Booth
Description:
Demolish exist maintenance/laundry bldg down to existing foundation slab. Construct new single story wood framed maintenance/laundry bldg on existing slab
Permit Reviews
Permit Number - TC-COM-0324-00518
Permit Status: Inspections
Permit Description: Demolish exist maintenance/laundry bldg down to existing foundation slab. Construct new single story wood framed maintenance/laundry bldg on existing slab
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/26/2024 | COMMERCIAL REVIEW - FULL v.3 | 09/24/2024 | APPROVED |
| 07/25/2024 | COMMERCIAL REVIEW - FULL v.2 | 08/22/2024 | REQUIRES RESUBMIT |
| 03/25/2024 | COMMERCIAL REVIEW - FULL v.1 | 04/29/2024 | REQUIRES RESUBMIT |
| 09/24/2024 | RESTAMP - COMMERCIAL v.1 | 09/25/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-COM-0324-00518
Permit Status: Inspections
Permit Description: Demolish exist maintenance/laundry bldg down to existing foundation slab. Construct new single story wood framed maintenance/laundry bldg on existing slab
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 04/26/2024 | Post-Installed Anchor Inspection Report is required. |
| 04/26/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
| 09/24/2024 | AIR BALANCING REPORT IS REQUIRED. |
| 09/24/2024 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-0324-00518
Permit Status: Inspections
Permit Description: Demolish exist maintenance/laundry bldg down to existing foundation slab. Construct new single story wood framed maintenance/laundry bldg on existing slab
| Date | Description | Comments |
|---|---|---|
| 03/25/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 04/29/2024 | A minimum 0.019-inch (No. 26 galvanized sheet gage), corrosion-resistant weep screed with a minimum vertical attachment flange of 3 1/2 inches shall be provided at or below the foundation plate line on exterior stud walls. The weep screed shall be placed not less than 4 inches above the earth or 2 inches above paved areas and be of a type that will allow trapped water to drain to the exterior of the building. The water-resistive barrier shall lap the attachment flange. The exterior lath shall cover and terminate on the attachment flange of the weep screed. Per IBC 2512.1.2 Weep screeds Where porches, landings, garage aprons are located at same level as floor slab, provide concrete or CMU foundation curb or other approved means to achieve minimum 2 inch clearance between slab and stucco weep screed. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-0324-00518
Permite Description: Demolish exist maintenance/laundry bldg down to existing foundation slab. Construct new single story wood framed maintenance/laundry bldg on existing slab
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/10/2025 | COT - LCEL - Electrical Underground | N/A | Re-inspection required | Partial for all in one meter base 4-8-25, called at 1244 pm. No answer on pre all-unable to leave voicemail-mailbox full. Left site at 1255. 4/10/25: called at 12:51pm no answer. Arrived on site at 1:03pm no access to site |
| 03/27/2025 | COT - LCPL - Plumbing Final | N/A | Partial Pass | This inspection is for plumbing underground at laundry room for washer waste lines. |
| 04/10/2025 | COT - LCEL - Grounding/Bonding | N/A | Re-inspection required | Partial for all in one meter base 4-8-25, called at 1244 pm. No answer on pre all-unable to leave voicemail-mailbox full. Left site at 1255. 4/10/25: called at 12:51pm no answer. Arrived on site at 1:03pm no access to site |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-0324-00518
Permit Description: Demolish exist maintenance/laundry bldg down to existing foundation slab. Construct new single story wood framed maintenance/laundry bldg on existing slab
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2025 | COT - LCEL - Electrical Progress | Passed | Panel set for new laundry room. | |
| 04/17/2025 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. (laundry room building) 4/17/2025 | |
| 04/25/2025 | COT - LCEL - Electrical Underground | Passed | ||
| 04/25/2025 | COT - HCBU - Roof Nailing | Passed | ||
| 04/25/2025 | COT - HCPL - Sewer | Passed | ||
| 05/30/2025 | COT - LCEL - Electrical Intermediate | Passed | ||
| 05/30/2025 | COT - LCEL - Electrical Above Ceiling | Passed | ||
| 06/02/2025 | COT - LCME - Mechanical Intermediate | Passed | ||
| 06/06/2025 | COT - HCBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 06/06/2025 | COT - LCEL - Grounding/Bonding | Passed | ||
| 06/09/2025 | COT - HCBU - Exterior Clips/Sheathing | Passed | ||
| 08/13/2025 | COT - LCME - Mechanical Final | Passed | ||
| 08/13/2025 | COT - LCBU - Building Final | Passed |