Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Commercial Building
Apply Date:
02/24/2026
Applicant:
Dennis Caldwell
Description:
NEW LOADING DOCK TO AN EXISTING COMMERCIAL BUILDING . bUILDING IS TO REMAIN AS IT IS WITH NO ADDITIONAL SQUARE FOOTAGE ADDED.

Permit Reviews

Permit Number - TC-COM-0226-00264
Permit Status: Inspections
Permit Description: NEW LOADING DOCK TO AN EXISTING COMMERCIAL BUILDING . bUILDING IS TO REMAIN AS IT IS WITH NO ADDITIONAL SQUARE FOOTAGE ADDED.
Start Date Submittal Complete Date Status  
08/27/2026 SPECIAL INSPECTION REVIEW v.1 08/28/2026 APPROVED Review Details
05/13/2026 ADMINISTRATIVE v.1 05/13/2026 REQUIRES RESUBMIT Review Details
08/20/2026 SPECIAL INSPECTION REVIEW v.1 08/21/2026 APPROVED Review Details
04/21/2026 COMMERCIAL REVIEW - FULL v.2 05/13/2026 APPROVED Review Details
02/27/2026 COMMERCIAL REVIEW - FULL v.1 03/23/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0226-00264
Permit Status: Inspections
Permit Description: NEW LOADING DOCK TO AN EXISTING COMMERCIAL BUILDING . bUILDING IS TO REMAIN AS IT IS WITH NO ADDITIONAL SQUARE FOOTAGE ADDED.
Total Outstanding Activity Conditions - 4
Date Name
03/20/2026 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
03/20/2026 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Conditions

Permit Number - TC-COM-0226-00264
Permit Status: Inspections
Permit Description: NEW LOADING DOCK TO AN EXISTING COMMERCIAL BUILDING . bUILDING IS TO REMAIN AS IT IS WITH NO ADDITIONAL SQUARE FOOTAGE ADDED.
Date Description Comments
02/27/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
02/27/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
03/20/2026 A Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0226-00264
Permite Description: NEW LOADING DOCK TO AN EXISTING COMMERCIAL BUILDING . bUILDING IS TO REMAIN AS IT IS WITH NO ADDITIONAL SQUARE FOOTAGE ADDED.
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
10/16/2026 COT - LCEL - Electrical Underground N/A Partial Pass 10/16/26: verified 2-2", 1-1", & 4-4" schedule 40 conduits adjacent to Dock 2. Okay to backfill trench using shading materials.
11/06/2026 COT - LCBU - Preslab N/A Canceled 11/6/26: reinforcement at truck verified under TD-DEV-0226-00042.
11/06/2026 COT - LCBU - Excavation/Rebar/Zoning N/A Partial Pass 11/6/26: Reinforcement/Excavation at truck bay verified per TD-DEV-0226-00042 plans- details 102 & keynotes #4 & 5. Okay for concrete placement.

Documents

File Name Document Type  
CCD - LOADING DOCK SI CERT-2026-08-24_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
LOADING DOCK SIC-2026-08-18_V1.PDF DOCUMENTS VIEW
COMMENT RESPONSE LETTER-_V1.PDF DOCUMENTS VIEW
CONS-25055-REV1-SET-4-20-2026_V2.PDF DOCUMENTS VIEW