Permit: TC-COM-0225-00361
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
4811 E GRANT RD UNIT 141
Address NEW:
4811 E GRANT RD UNIT 141
Apply Date:
02/20/2025
Applicant:
Arturo Zatarain
Description:
FRIDAY PILATES - vanilla shell T.I. No additional square footage. Architectural work only.
Permit Reviews
Permit Number - TC-COM-0225-00361
Permit Status: Complete
Permit Description: FRIDAY PILATES - vanilla shell T.I. No additional square footage. Architectural work only.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/26/2025 | COMMERCIAL REVIEW - LIMITED v.1 | 03/17/2025 | APPROVED |
| 04/04/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/08/2025 | APPROVED |
Conditions
Permit Number - TC-COM-0225-00361
Permit Status: Complete
Permit Description: FRIDAY PILATES - vanilla shell T.I. No additional square footage. Architectural work only.
| Date | Description | Comments |
|---|---|---|
| 03/14/2025 | By virtue of a space being split into two separate tenant spaces, a new address must be assigned to the new tenant space. The remaining tenant space can keep the existing address which will also need to apply for a new permit leading to a new Certificate of Occupancy reflecting the smaller tenant square footage and space reconfiguration. Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 Ensure to make the necessary corrections the address for this building permit.and the drawings as necessary. | |
| 02/26/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 03/13/2025 | NESHAP Permit is required. (Utilized with commercial demolition permits) | |
| 03/14/2025 | THE MEANS OF EGRESS WILL BE ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. IBC 1008.2.1 Ensure that the lighted exit sign, emergency light with back-up power as well as the fire extinguisher are all functioning complying to code. | |
| 03/14/2025 | Artificial light shall be provided to an average illumination of 10 footcandles at a height of 30 inches above the floor level. Section 1008.2 requires 1 footcandle of light at the walking surface of all means of egress. IBC1204.3 |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-0225-00361
Permite Description: FRIDAY PILATES - vanilla shell T.I. No additional square footage. Architectural work only.
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2025 | BULD - Electrical Clearance | N/A | Not Applicable | |
| 05/05/2025 | COT - FCON - Alarm - Final | N/A | Not Applicable | |
| 05/05/2025 | COT - LCPL - Plumbing Final | N/A | Not Applicable | |
| COT - FCON - Fire - Final | N/A | Not Ready | Need to address Sprinkler comments. | |
| COT - FCON - Sprinkler - Final | N/A | Not Ready | Will need to add or relocate 4 sprinkler heads that are too far away from new wall. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-0225-00361
Permit Description: FRIDAY PILATES - vanilla shell T.I. No additional square footage. Architectural work only.
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2025 | COT - LCBU - Framing | Passed | ||
| 05/05/2025 | ENGR Engineering Final | Passed | ||
| 05/05/2025 | COT - LCME - Mechanical Final | Passed | ||
| 05/05/2025 | COT - LCBU - Building Final | Passed | ||
| 05/05/2025 | COT - LCEL - Electrical Final | Passed | ||
| 05/12/2025 | COT - FCON - Fire - Final | Passed | ||
| 05/12/2025 | COT - FCON - Sprinkler - Final | Passed |